Nova Biomedical - StatStrip Xpress
by Nova Biomedical

Follow Us
DESCRIPTION
StatStrip provides the analytical performance for those testing situations where glucose meter interface capability is not needed.

The introduction of StatStrip Xpress provides hospitals a choice of glucose monitors with or without a connectivity solution using the same Multi-Well test strip. 
 
Like the StatStrip™ Glucose Hospital Meter, StatStrip Xpress elevates bedside glucose testing to a new level of analytical performance that approaches the quality of central laboratory testing.It incorporates a new strip technology that uses four measuring wells.Nova’s Multi-Well system measures and corrects hematocrit interference, as well as interferences from acetaminophen (Tylenol), uric acid, ascorbic acid (Vitamin C).StatStrip Xpress also eliminates oxygen, maltose, galactose, and xylose interferences.Freedom from interferences, coupled with excellent correlation to central laboratory reference methods, provides improved accuracy compared to conventional meters and strips.    
   
StatStrip Xpress’ 6-second analysis time, small 1.2 microliter sample size, and simple operating steps make bedside glucose testing fast and easy.Unlike competitive glucose analyzers, StatStrip Xpress requires no calibration codes.This eliminates a potential error source, reduces the number of steps required for testing, and allows StatStrip Xpress manufacturing lots to be used interchangeably.

FORUMSView All (8)
Ask a New Question

0

Replies
-M.mahrous
8 years ago
Purchase

I want to purchase one for medical research

Reply

0

Replies
-dcarlantonio
8 years ago
Date Change

How can the date be changed on the Stat Strip Xpress monitor?  We just realized that the date is a day behind.  Possibly due to leap year?  There are no instructions as to how to change it.  Thank you for any assistance you can provide.

Reply

0

Replies
-Linda Mc
8 years ago
Medical Assistant

We perform POC glucose testing with your instrument in our office and have been informed that we must report a reference range with each result.  Is there a reportable reference range for this instrument?

 

Linda

 

Reply

FEATURES

       
  1. LCD black/white display    
  2. Large numeric display (30 mm)    
  3. Traditional QC with target values assigned to QC materials    
  4. Units of measure based on meter ordered (mg/dl or mmol/L models)    
  5. Auto-shut off of meter when not in use    
  6. Automatic sample detection and analysis start    
  7. Automatic sample counter with date/time stamp for data tracking   

SPECIFICATIONS

Height3.6 in
Length 0.9 in
Weight0.2 lbs
Width2.3 in
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.