Beckman Coulter - UniCel DxH 800 Coulter
by Beckman Coulter

Follow Us
DESCRIPTION
The first step in the transformation journey.

Today’s hematology laboratories are challenged by ever-increasing pressure to improve productivity, decrease turnaround time and reduce overall costs. The UniCel DxH platform is designed to meet these challenges head-on and transform your laboratory, with unparalleled quality of results, innovative efficiency solutions and revolutionary scalability. Heralding a new era of hematology solutions, the UniCel DxH 800 delivers the ultimate in high-definition cellular analysis. This is just the beginning of the transformation journey. Partner with us to see what the future holds.

FORUMSView All (10)
Ask a New Question

1

Reply
-Powsiya Jahn
a year ago
What is the methodology for DXH 800 for HB
What is the methodology for DXH 800 for HBReply

2

Replies
-Kimba1650
5 years ago
software
We purchased a used DXH800 from ebay for our students in a MLT program. I am missing the software. Does anyone know where to download it from or is willing to share it? Please help!Reply

0

Replies
-lovelle
7 years ago
Lovelle Rempel

Moving Average . how to use it? Also as Beckman is having problem with body fluid QC and we have to calculate our SD , can you tell me how to format it. in SEtting. About Moving average is it a CAP requirement or not?

Reply
DOCUMENTS / MANUALSView All

FEATURES

  • Single aspiration pathway simplifies calibration and quality control process while eliminating mode-to-mode issues       
  • Sample Aspiration Module (SAM), with its unique design, reduces aspiration volume, especially benefiting pediatric samples       
  • 2D-Digital Bar Code Technology maximizes reading capability, preventing errors and reducing misreads       
  • Remote Management System (RMS) increases versatility by proactively performing diagnostics with real-time troubleshooting, leading to increased instrument uptime       
  • Specimen Transport Module (STM) uses a unique, patented magnetic system for continuous loading of up to 20 cassettes, allowing “load 'n' go” capability       
  • Intelligent workload distribution optimizes workflow by achieving rapid turnaround times, providing STAT and ER results quickly       
  • Provides automation in a small footprint       
  • On-board tracking, for optimal reagent management       
  • With its future upgradability the UniCel DxH 800 can be converted to a full laboratory workcell, providing tomorrow’s platform today       
  • High Definition Cellular Analysis on the UniCel DxH 800 provides four times greater resolution and achieves new levels of performance       
  • Flow Cytometric Digital Morphology (FCDM) optimizes performance by providing 10 times more data per sample than existing technologies, allowing reduced review rates       
  • With its multi-angle scatter technology, onboard reagents and new advanced algorithms, the UniCel DxH 800 provides an unrivaled NRBC, with no need for special or expensive stains       
  • Using its data fusion capability, the system will correct for most of the common interferences in today’s laboratory, ensuring first-pass accuracy and efficiency
  • SPECIFICATIONS

    Height38 in
    Length 31 in
    Weight260 lbs
    Width30 in

    Additional Specifications

    Throughput      
    Up to 100 samples/hr      
    Aspiration Volumes      
    Open/Closed Vial 165 µL      
    Power      
    90–264 VAC and 48–62 HZ      
    DxH 800 System with System Manager and printer draws 1,185 watts      
    DxH 800 System with System Manager, printer and UPS draws 2,390 watts      
    Data Management      
    Computer Microsoft* Windows* XP      
    Database 40,000 Patient results with Graphics      
    Quality Assurance QC with Levy-Jennings Graph, XB/XM for Moving      
    Averages, Daily Check, Intelligent Quality Monitoring      
    Sample Transport Capabilities      
    Capacity 20 five-tube cassettes      
    Bar Codes Digital Bar Code with 2D Bar Code capability      
    Sample ID Up to 22 characters

    NEWSView All

    Device Alert

    Problem: In a February 11, 2011, Urgent Product Correction letter submitted by an ECRI Institute member hospital, Beckman Coulter states that the above analyzers may experience the following problems: (1) Specimen tubes may fall out of a type A cassette (product number A53551) when the analyzer inverts the cassette in the mixing station or ...

    FDA AlertsView All

    Beckman Coulter Life Sciences Recalls DxH800 and DxH600 and DxH...

    Beckman Coulter is recalling the DxH 800, DxH 600, and DxH 900 Hematology Analyzers due to sporadic erroneously elevated platelet count results without flags or system messages, meaning there is no way for the laboratory operator of the test to recognize the error.