Hitachi Medical Systems - Echelon
DESCRIPTION
Hitachi’s Echelon 1.5T provides outstanding imaging performance today and is the basis for high performance far into the future.
Echelon’s high performance 1.5T magnet, ultra fast 150T/m/sec slew rate gradient system, 8 channel RF receiver (with a 16-channel XLS option), and wide range of multi-channel receiver coils provide unmatched value as a data acquisition platform.
FORUMSView All (4)
1Reply4 years ago | MRI 1.5T need a service and user manual for MRI Hitachi Echelon Oval 1.5 T Reply |
3Replies10 years ago | service manual want service manual for CT Scan machine Reply |
0Replies13 years ago | Echelon XL imaging suite Hitachi’s Echelon XL clinical and vascular imaging suites provide sequences, tools and features such as RADAR radial acquisition and Fluoro triggered bolus MRA. Tools include MIP, MPR, vascular volume rendering, dynamic analysis and ADC and isotropic DWI analysis. ORIGIN MR operating software incorporates a graphical user interface, and the layout intuitively guides the operator from patient registration through image archiving. An integrated image quality calculator informs the technologist of the impact parameter changes will have upon the image. Intelligent parameter guidance displays options to begin scanning. Echelon's magnet delivers high homogeneity, and the standard per patient higher order active shim enables optimized general image quality and uniform RF fat saturation, the company says. It has a weight limit of 500 pounds and a 61-centimeter bore, and the table has more than nine feet of table travel and lowers to 19.5 inches. Echelon's computer system integrates a multiprocessor CPU and an advanced scan/reconstruction engine. [url=http://www.medicaldealer.com/article.aspx?Id=1113]Originally published in MedicalDealer Magazine.[/url]Reply |
SERVICE COMPANIESView All MRI Systems Companies
FEATURES
- Clinical Suite
- SE, IR, FSE, FIR, DE-FSE, DE-FIR [*] GE, SG, BASG, RSSG
- DWI
- RADAR radial acquisition
- RAPID Parallel Imaging
- Water Excitation
- Regional Shim
- Vascular Suite
- TOF
- FLUTE Fluoro-triggered bolus MRA
- TRAQ Time-resolved MRA
- VASC Non-contrast MRA
- Tools
- MIP
- MPR
- Vascular volume rendering
- Dynamic analysis
- ADC and isotropic DWI analysis
- ORIGIN MR operating software
- Rapid registration mode
- Drag-and-drop patient directory management
- Anatomically-grouped protocol lists
- Easy-to-save site specific protocols
- Hitachi-recommended protocols
- Magnet, Gantry and Patient Amenities
- 1.6 meter gantry
- 61 cm bore
- Up to 500 lbs weight limit
- Over 9 feet of longitudinal table travel
Weight | 5150 lbs |
Clinical Use | Whole Body |
Gantry (Max. Clearance) | 61 cm |
Magnetic Field Strength | 1.5 T |
Patient Weight Capacity | 500 lbs |
NEWSView All
Echelon XL imaging suite
Hitachi’s Echelon XL clinical and vascular imaging suites provide sequences, tools and features such as RADAR radial acquisition and Fluoro triggered bolus MRA. Tools include MIP, MPR, vascular volume rendering, dynamic analysis and ADC and isotropic DWI analysis. ORIGIN MR operating software incorporates a graphical user interface, and the layout ...
Product Focus Radiology Market Analysis Magnetic Resonance...
by: John Buie via MD Publishing Since its introduction, Magnetic Resonance Imaging (MRI) has become a ubiquitous diagnostic tool. It now represents one of the most rapidly expanding sectors in the medical imaging market. It has been claimed that all medical imaging segments are on the cusp of a major new phase of growth. This imminent ...