Roche Cobas C 111

Share:

Cobas C 111

The cobas c 111 analyzer is a tabletop system designed to set the next gold standard in automated clinical chemistry testing for small laboratories.

With key components such as optics, reagents and calibrators taken from larger COBAS Integra and cobas blood gas systems used in reference labs and hospitals, the cobas c111 system joins a family of analyzers designed to deliver consistent results from the smallest to the largest system.
Cobas C 111
Attributes
Additional Specifications Test throughput 60-85 photometric tests/hr 180 ISE tests/hr 60-100 tests/hr photometric and ISE mixed

Sample types Serum, plasma, urine, whole blood (HbA1c)

Sample input Continuous loading of primary and secondary tubes into 8 sample positions

Sample container types
Primary tubes: 5-10mL; 16x100, 16x75, 13x100, 13x75
Sample cup: 2.5 mL
Micro cup: 1.5 mL
Cup on tube: Cup on 16x75mm tube
Cup on top of one non standard tube

Sample volume Min. sample volume:
Primary tubes 500µL
Sample cup 75µL
Micro cup 50µL

Photometer 12 wavelengths, 20 W halogen lamp, monochromatic and bichromatic measurement

Measurement principles Absorbance photometry (enzymes, substrates, specific proteins)
Ion selective electrode, indirect measurement (dilution 1:6)

Control unit 5.7” color touch-screen LCD (1/4 VGA)

System interfaces 2 x RS 232 serial interface, bi-directional (ASTM protocol) for host and barcode scanner 2 x USB 1.1/2.0 for modem and memory stick (data loading and backup)

Electrical requirements
Line voltage 100-125 V and 200-240 V AC (-15%, +10%)
Line frequency 50 Hz (±5%) and 60 Hz (±5%)
Power consumption 250 VA (320 VA with ISE)
Installation category II (IEC 61010-1)

Physical dimensions (with ISE)
Width: 590mm (720mm)
Depth: 550mm (550mm)
Height: 480mm (480mm)
Weight: 32.3kg (35kg)

Water requirements Up to 2 liters/day NCCLS Type II (conductivity <1µS/cm at 25°C)

Regulatory requirements GS, CE, UL, C-UL

Features


    Increased flexibility without sacrificing performance
  • Automated sample and reagent pipeting allows operators to walk away for 45-60 minutes
  • Connectivity options for testing and data management
  • Up to 65 photometric tests/hour and 180 electrolyte tests/hour (85-100 tests/hr combined)
  • Onboard capacity for up to 17 tests at a time (3 ISEs & 14 photometric tests)

    Convenient and easy to use
  • Intuitive user interface simplifies use for different skill and access levels
  • Continuous loading and unloading of virtually any sample tube or cup
  • Cooled, exchangeable reagent disks make loading flexible and efficient
  • Software-driven operation for minimal maintenance and maximum uptime

    Extensive menu
  • Currently more than 30 assays, with more planned for release in the near future
  • Covers the basic and comprehensive metabolic panels, electrolyte and lipid panels, hepatic and renal function panels.
  • Includes innovative tests such as whole blood HbA1

Photos

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@medwrench.com

Instrument Documents

Picture of Roche Cobas C 111
At Roche we focus on developing medicines and diagnostics that will help patients live longer, better lives.

We strive to address unmet medical needs...

More about Roche

Visit Roche

Questions and Answers

Recent Question Activity

Ask a Question

Serial Interface

Machine is not sending data correct , It is sending 4 ,5 only Whats this issue???

CRYSTALS IN ISE REFERENCE TUBING

I keep getting error messages on my c111 that the ise ref cant continue because it detected air in the tubing. I aslo noticed crystals in the ise reference tubing which I suspect is the source of the problem..what do I do??

barcode scanner

Barcode scanner which has come with cobas c111 is not sending the scanned data to terminal except the sample data which is given,so wats the format for it

See all 12 Roche Cobas C 111 Questions and Answers There are 12 Threads

Preventative Maintenance

Keep your instrument running smooth

There are no threads in Roche Cobas C 111 Preventative Maintenance at this time.
Add Preventative Maintenance Post

Reviews

Member Reviews

There are no threads in Roche Cobas C 111 Reviews at this time.
Add a Review

MedWrench is in association with:

LabWrench TechNation Medical Dealer OR Today MD Expo LabX