Can anyone please provide me with protocol specifications of advia 1200 for communication between it and a host computer?
Read Post
- Forum: Siemens ADVIA 1200 Questions and Answers
- Last Post: May 15th, 2013
- 0 Replies
- Post a Reply
| Attributes | |
|---|---|
| Height | 110.8 cm |
| Length | 85 cm |
| Weight | 450 kg |
| Width | 122 cm |
| Additional Specifications | Sample handling Sample Tubes 2 mL, 5 mL, 7 mL, 10 mL, sample tubes/cups, microcontainer tubes Sample Tray 84 samples, continuous loading, positive sample identification STAT Positions User-defined option for up to 84 dedicated positions Bar Codes Interleaved 2 of 5, code 39, code 128, Codabar (NW7) Auto-repeat Automatic repeat testing from the original sample Auto-dilution Automatic dilution from the original sample Reflex Testing Ability to perform 3 additional tests based on results of first test Liquid Level Sensing Capacitance technology Crash Prevention Spring loaded sensor prevents sample probe crashes Clot Detection Automatic alert when clot or clog detected Original Sample Volume 1 to 25 µL; system uses from 1-5 µL for most tests Reaction area Reaction Tray 231 reusable plastic cuvettes Cuvette Optical Path Length 10 mm Reaction Bath Inert fluorocarbon oil circulation system, 37°C Photometer 14 fixed wavelengths Light Source 12V, 50W halogen lamp, cooled by forced water circulation Assay Methods Endpoint, rate reaction, 2-point rate, multi-point homogeneous immunoassays Reaction Times 3, 4, 5, and 10 minutes Automatic Correction Serum blank, cell blank, measurement point change, sample volume change in reassay Point Forwarding Automatically extends linearity for over assay range samples Reactant Volume 80-430 µL Reagent handling Reagent Capacity 41 colorimetric methods Reagent Tray 2 trays, 45 position each, refrigerated Dispensing System 2 probes with liquid level sensing Reagent Wedges 20, 40, 70 mL bar-code labeled wedges Reagent Inventory Management Tracks tests remaining, lot number, on-board stability and expiration date Reagent Dilutions Capability to dilute concentrated reagents on-board Open system capability Channels 100 channels, includes user-defined applictions Bayer 3rd party applications Varies by country; can be configured on system ISE ISE Indirect simultaneous measurement of Na+, K+, Cl- Sample volume 22 µL for all three tests Priming Automatic priming cycle Electrode shelf life 30,000 tests per electrode Throughput rate 600 tests per hour Calibration Calibration stability Average 14 days Auto-Calibration User-defined time interval or with new reagent container View Calibration Curve Graphical display of calibration curve via software Calibration/Control tray 61 refrigerated positions for calibrators, controls and diluents Data management Operating System Microsoft Windows XP Professional System documentation Operator manual and instructions for use on-line and on CD Host interface RS232c bidirectional Data Storage 70,000 patient samples On-board maintenance logs Schedule and monitor routine maintenance activities via software |
Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@medwrench.com

Can anyone please provide me with protocol specifications of advia 1200 for communication between it and a host computer?
Read Post
WHAT IS THE WATER TYPE REQUIOREMENT FOR ADVIA 1200
WHAT IS THE WATER TYPE REQUIREMENT FOR ADVIA 1200 CHEMISTRY SYSTEM, IS IT TYPE I, TYPE II, OR TYPE III
Read Post
There are no threads in Siemens ADVIA 1200 General Comments at this time - be the first to Post New Comment
There are no threads in Siemens ADVIA 1200 Preventative Maintenance at this time - be the first to Add Preventative Maintenance Post
Press releases and Articles
Digital imaging solution offers state-of-the-art X-ray technology for smaller budgets....
Study findings suggests potential use of -T808 as PET imaging agent for tau protein pathologies associated with Alzheimer’s disease...
Siemens Healthcare has launched five new mobile solutions that help provide imaging specialists and referring physicians with secure access to...
There are no threads in Siemens ADVIA 1200 Reviews at this time - be the first to Add a Review