The Unify CRT-D offers the highest energy, capture confirmation in all chambers for enhanced safety and clinic efficiency, and a smaller size. The device and its extensive feature set were designed for safety and reliability with extended longevities of 6.6 years.

FORUMSView All (8)
Ask a New Question

1

Reply
-Adri
9 years ago
cavitron device at the dental office

I'm a dental hygienist and want to know if a cavitron device can be used on pt's with this device.

 

Adriana

Reply

0

Replies
-wwallace
9 years ago
Model CD3365

I cannot find any reference a model cd3365 on the internet. I was given one last week and would like to have more info on this unit.

Reply

0

Replies
-BHarts
10 years ago
Telemetry Transmission

I was talking with a gentleman planning to move into one of our apartment buildings.  He has a CD3231-40Q unit and indicated that it is monitored 24/7 and needs a phone line, although he only has one phone line and can still use it for calls while the monitoring is going on.  Do you have some literature on how this transmission works so that I can provide the correct communications for him when it is time to move?   Many thanks.

Reply
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Defibrillator Companies

FEATURES

  • DF4 connector is designed to simplify implants by streamlining defibrillation connections into a single terminal pin and reducing the number of set screws  
  • Decreased device footprint and volume with the most narrow (40 mm) design available for greater patient comfort and range of motion during activity
  • BiVCap®, LVCap™, RVCap® and ACap® Confirm features promote patient safety by automatically ensuring capture of the myocardium in response to pacing stimuli in the left ventricle, right ventricle and right atrium
  • Triggered Pacing with BiV Trigger Mode helps maintain a high percentage of BiV pacing by triggering pacing in both the left and right ventricles in response to a sensed ventricular event
  • Negative AV hysteresis with search promotes ventricular pacing by automatically reducing the AV delay when intrinsic activity is present, thereby promoting a high degree of ventricular pacing  
  • QuickOpt® timing cycle optimization provides quick and effective optimization for more patients at the push of a button  
  • The low frequency attenuation filter is designed to enhance sensing performance and may reduce the possibility of over sensing T waves
  • Unique AF Suppression™ algorithm is clinically proven to suppress episodes of paroxysmal and persistent AF. Studies show a 25% decrease in symptomatic AF burden
  • DeFT Response® technology tools provide more clinically proven, noninvasive options for managing high DFTs  

SERIES MODELS

St. Jude Medical, Inc. - CD3231-40

St. Jude Medical, Inc. - CD3231-40Q

NEWSView All

St. Michael's Hospital First In Ontario To Implant Powerful New...

22 Dec 2010 St. Michael's Hospital has just become the first in Ontario to implant a small but powerful new defibrillator into a patient's chest. The defibrillator - about the size of a Zippo lighter - is the smallest available in terms of surface area and can deliver the highest level of energy, 40 joules. The narrow shape of the device a...

News Release-St. Jude Medical Announces FDA Approval of Unify...

New products help ensure effective therapy delivery, have longer battery life and can be implanted through a smaller incision due to reduced size. ST. PAUL, Minn. – May 12, 2010 – St. Jude Medical, Inc. (NYSE:STJ), a global medical device company,

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree