The Carbon XL-2 is ideal for distributed applications such as inside the exam room or even a trauma bay with a speed of up to 92 images an hour and image previews in as little as 23 seconds. With that flexibility, the Carbon XL-2 is also a great redundancy solution during peak periods. The XL-2 also features a 50 Reading Mode* for sharp, excellent detail — ideal for extremity exams or anywhere that seeing fine details is critical.   
   
The Carbon X is designed for smaller facilities with variable caseloads or remote applications with throughput speeds of up to 72 images/hour. It can supplement a DR room or offer redundancy when needed. Either way, there's a FCR Carbon to fit your needs and your space perfectly.
FCR Carbon XL-2
Attributes
CR-System Configuration Single-plate floor unit
CR-Workstation Configuration Included device for one or more image readers
Mammography Support No
Scoliosis Imaging Yes
Height 31.9 in
Length 15 in
Weight 216 lbs
Width 23.2 in
Additional Specifications Throughput (@ 14x17, std resolution) 87 plates per hour   
Image plate DQE Proprietary percent at 2 lp/mm   
Reader laser spot size50 & 100 microns   
Output grayscale resolution 12 bits/per pixel   
Preview image display time 3 seconds

Features

       
  • Fast image previews beginning in as little as 10 seconds   
  • Quick throughput - XL-2: 62-92, Fast Scan mode: 87 images/hr 14x17" X: 43-72 images/hour   
  • 100 micron 10 pixels/mm Standard Reading Density   
  • Image Reading 12 bits gray scale, output: 10 or 12 bits   
  • Small 2.4 sq. ft. footprint   

Photos

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@medwrench.com

Picture of Fujifilm FCR Carbon XL-2
Fujifilm has redefined its corporate mission, vision and values, and at the core is our commitment to create superior healthcare experiences for each...

More about Fujifilm

Visit Fujifilm

Questions and Answers

Recent Question Activity

Ask a Question

Lamp Error

I know this probably sounds crazy, but if I have a Fuji Carbon XL and it is giving a lamp error, can it be anything other than the lamp needing replacement?

How to change the Target ip of a cr-ir368

Hello We have a Fujifilm clearview cr-ir368 and I need to change the destination address for the PACS. I am not sure how to do this.

Repeat rates

I cannot remember how to acquire the number of rejected images per tech.

See all 6 Fujifilm FCR Carbon XL-2 Questions and Answers There are 6 Threads

Preventative Maintenance

Keep your instrument running smooth

There are no threads in Fujifilm FCR Carbon XL-2 Preventative Maintenance at this time.
Add Preventative Maintenance Post

Reviews

Member Reviews

There are no threads in Fujifilm FCR Carbon XL-2 Reviews at this time.
Add a Review

MedWrench is in association with:

LabWrench TechNation Medical Dealer OR Today MD Expo LabX