Boston Scientific Endostat II

Endostat II

Endostat II Microvasive Electrosurgical Unit has an integrated peristaltic pump for enhanced site visualization; impedance-matched bipolar output automatically limits power to avoid tissue charring; user-adjustable time selection for automatic power deactivation.
Endostat II
Attributes
OutPut Frequency 550 kHz -750
Output Power 150 W
Height 13 cm
Length 15.5 cm
Weight 24 kg
Width 6.3 cm
Additional Specifications SYSTEMS        
Monopolar: Cut(blend), coagulate       
Max. energy output ( at rated ohms) (SYSTEMS): Up to 150 Watt95       
Max voltage, vp-p (SYSTEMS): 700       
Max. energy output ( at rated ohms) (SYSTEMS): Up to 150 Watt70       
Max voltage, vp-p (SYSTEMS): 700       
       
Bipolar (SYSTEMS): Continuous, cont irrigation, var time       
Max. energy output ( at rated ohms) (SYSTEMS): Up to 150 Watt70       
Max voltage, vp-p (SYSTEMS): 175       
Max. energy output ( at rated ohms) (SYSTEMS):U p to 150 Watt70       
Max voltage, vp-p (SYSTEMS): 175       
   
POWER NEEDED, VAC (ENERGY): 115 USA, 100 Japan       
       
GENERATOR: Solid-state       
       
Frequency, khz: 550-750

Features

MICROVASIVE ENDOSTAT II ESU UNIT WITH:       
           
  • BIPOLAR, MONOPOLAR, CUT,COAG, BLEND, IRRIGATION, AND FOOTSWITCH        
  • RF WATTAGE       
  • LED DISPLAY       
  • CONTINUITY ALARM       
  • VARIABLE SPEED PERISTALTIC PUMP       

Photos

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@medwrench.com

Instrument Documents

Picture of Boston Scientific Endostat II
From its humble beginnings in a small laboratory in Massachusetts, Boston Scientific has grown and then honed its core to over 25,000 people world-wide,...

More about Boston Scientific

Edit This Equipment

Visit Boston Scientific

This instrument was added by: MedWrenchManager

Questions and Answers

Recent Question Activity

Ask a Question

Bipolar testing

I need a copy of the load variation chart for the Endostat II that indicates what the wattage should be at 50 ohms. My ESU analyzer does not go down to 25 ohms.  
Read Post

gangadin

I have Endostat II. I tried snare polypectomy on power range of 25-30, but it did not work. How much power do I need for snare polypectomy with this equipment?
Read Post

General Comments

Post your thoughts

Post New Comment

There are no threads in Boston Scientific Endostat II General Comments at this time - be the first to Post New Comment

Preventative Maintenance

Keep your instrument running smooth

Add Preventative Maintenance Post

There are no threads in Boston Scientific Endostat II Preventative Maintenance at this time - be the first to Add Preventative Maintenance Post

Reviews

Member reviews

Add a Review

There are no threads in Boston Scientific Endostat II Reviews at this time - be the first to Add a Review

MedWrench is in association with:

LabWrench TechNation Medical Dealer OR Today MD Expo LabX