GE HealthCare - AMX 4 Plus
DESCRIPTION
Non-stop, Portable PerformanceWhen you need to get to a patient fast, you need a durable, mobile X-ray imaging system. GE Healthcare’s AMX-4+ analog X-ray system answers that challenge by providing high-performance in a compact, easy-to-maneuver package. The rotating arm and tube simplify positioning and facilitate bedside studies, while the maintenance-free battery produces up to 50 high-quality exposures with a single charge.
FORUMSView All (166)
2Replies2 months ago | Starts to Rotor then shuts down. Hello, To start at the beginning ... 1st) Tube/collimator was tough to move up/down to column. Replaced upper brake to column, brake wires shorted to housing when re-assembling. Repaired wires, routed wires a different way, re-assembled ... Tube/collimator easy to move up/down. Charged portable overnight, next day went to verify system working before giving to the techs .... rotor cuts out in 2 seconds & system restarts, tests passed, no errors, CB never trips off. 2nd) Now AMX-4 + when you rotor from Hand switch, can hear relays click, 2 seconds later the displays go blank and startup test pass, display is ready again. I can hear the rotor spinning in tube, tube resistance is good. I verified capacitor values on right side. All fuses are good. Reseated Relays on circuit boards. I have a replaced 1 board at time to the following .... Display Bd, CPU, Rotor Bd, FIL/Kvp Bd. No errors appear after startup tests. Can't do any cals because rotor doesn't last but 2 seconds. Does anyone have any other idea's? Thanks Jeremiah Equipment: GE HealthCare - AMX 4 Plus Reply |
0Replies3 months ago | Error 431 & 433 I have facing problem when exposure button is pressed error papers 431 & 433 any help to resolvsolve this Reply |
1Reply9 months ago | Test4 failed Turned on AMX4 but test4 failed please help how to solve it Equipment: Amx4 Reply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Mobile Radiography Companies
FEATURES
[list] [*]Dual drive motors and oversize casters facilitate movement; even in taxing environments. [*]Ease of use, effortless maneuverability and 270 degree column rotation add positioning flexibility across diverse care areas and exams, even in tight spaces. [*]Large installed base results in operator familiarity, reducing training costs. [/list]
Maximum Focal Spot | 0.75 mm |
Height | 70 in |
Length | 45 in |
Weight | 1080 lbs |
Width | 25 in |
Additional Specifications
Remote x-ray control: Handswitch-Standard