Attributes
Height 30 cm
Length 32 cm
Weight 7.7 kg
Width 10.5 cm
Additional Specifications Type (protection against electric shock):      
Class I Equipment, Type BF and/or CF depending on Function Units      
      
Laser: (only PF 5001)      
IEC 60825-1 Class 1 (CFR 1040.10 Class I) Solid-state diode laser, 780 nm wavelength. Maximum power output at probe tip 1 mW.      
      
Mains and Power consumption:      
100 - 240 VAC, 50 - 60 Hz, 70 VA (with four Function Units)      
      
Dimensions:      
30 x 32 x 10.5 cm      
      
Weight:      
7.7 kg (with four Function Units)      
      
EC Declaration of conformity:      
CE approved according to MDD 93/42/EEC, Electrical Safety Standard IEC 60601-1, Class I EMC Standard IEC 60601-1-2      
      
Operating conditions:      
+10 to +35 °C at 30-85% RH      
      
Output:      
RS-232 output to computer or directly to printer Analog: -10 to +10 V      
      
      
      
 

Features

       
  • Adaptable - combine modules to suit your application   
  • Expandable - increase number of sites with ease   
  • Dedicated analysis software   

Photos

  • PHOTO_1
  • Perimed Periflux System 5000
PHOTO_1

PHOTO_1

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@medwrench.com

Instrument Documents

Picture of Perimed PeriFlux System 5000
Perimed AB, established in 1981 and headquartered just outside Stockholm, is the world leader in developing, manufacturing and marketing state-of-the-art...

More about Perimed

Visit Perimed

Questions and Answers

Recent Question Activity

Ask a Question

shirley RN

when pressing the cal button what is the code E20 please? I seem to get that and have to turn the machine off and restart.

bad lead/cable

I have a Perimed PF5002 tcpO2 monitor that has a bad lead/cable. The cable PN is E5250. Perimed wants $2150.00 for a new cable. Does anyone know of any secondary source for replacement cables or repair.

There are 2 Threads

Preventative Maintenance

Keep your instrument running smooth

There are no threads in Perimed PeriFlux System 5000 Preventative Maintenance at this time.
Add Preventative Maintenance Post

Reviews

Member Reviews

There are no threads in Perimed PeriFlux System 5000 Reviews at this time.
Add a Review

MedWrench is in association with:

LabWrench TechNation Medical Dealer OR Today MD Expo LabX