Toshiba - Aquilion RXL
by Toshiba

Follow Us
DESCRIPTION
Aquilion RXL is a new whole-body multislice helical CT system with a 32 mm wide detector

The Aquilion RXL offers maximum performance for customers needing to perform a wide variety of routine clinical examinations in a streamlined workflow, with the objective to deliver the best diagnostic quality at a minimal amount of radiation. Provides the industry’s best low-contrast resolution of 2 mm @ 0.3% with low exposure dose. Incorporating Quantum Detector technology and state-of-the-art dose reduction technologies. 
 
16-Slice Configuration 
Entering the world of the Aquilion family with adaptive iterative dose reduction technology (AIDR 3D) and active collimator for ultra low dose scanning. 
 
32-Slice Configuration 
Aquilion reliability combined with double slice reconstruction for outstanding spatial resolution and extended flexibility.  
 
Low Dose Examinations This system incorporates a variety of functions that can significantly reduce the patient exposure dose, such as AIDR 3D, as standard. 

     
  1. AIDR 3D 
  2. SUREExposure™ 3D Adaptive (automatic exposure control) 
  3. Active Collimator 
  4. Dose Management Functions – Dose Check/Dose Report 
     

FORUMSView All
Ask a New Question
SERVICE COMPANIESView All CT Scanner Companies

FEATURES

With the integration of AIDR 3D into SUREExposure controls, radiation exposure is automatically reduced before the scan, ensuring that the lowest possible dose is employed for the specific diagnostic objective irrespective of the size or shape of the patient. AIDR 3D integrated in SUREExposure 3D Adaptive can be applied to all acquisition modes for routine clinical use and is able to remove up to 50% of image noise resulting, which corresponds to a dose reduction of up to 75% by the same Standard Deviation (SD) for noise.  
 
Key features of AIDR 3D:
 

     
  1. Full integration in scan protocols for improved workflow 
  2. Dose reduction in clinical setting by up to 75% 
  3. Full automatic iterative reconstruction process 
  4. Minimal penalty in reconstruction times 
  5. Noise reduction and improved Spatial Resolution 
  6. Superb artifact suppression  
 
 
Lightning Speed 
The new console enables significant improvements in workflow, with faster reconstruction, automated processing,and remote access capabilities. With a reconstruction speed of up to 28* images per second (16 images per second for standard configuration), all the images are available in a flash, even when Toshiba’s unique 0.5 mm slice thickness is used. Furthermore, the enhanced DICOM protocol allows fast data transfer speed up to 60 images per second. Generation of MPR images can be performed automatically in accordance with the exam protocol setting. 
     
  1. High-Speed Reconstruction 
  2. Automated Processing 
  3. SUREXtension™ (Remote Access)* 
 
 
Latest Applications 
     
  1. Cardiac Examinations* 
  2. Colon View* 
  3. Lung Volume Analysis* 
  4. Vessel View* 
  5. Fat Index View* and more.. 

SPECIFICATIONS

Type (configuration)Multislice
Slices32
Gantry (Max. Clearance) 32 mm
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree