Philips - M3001A MMS Module
by Philips

Follow Us
DESCRIPTION

Module 

philips M3001A MMS Module Option A01. The Philips M3001A Multi-Measurement Module (MMS) is for use with the Philips IntelliVue (MP20-MP90) and M-Series (M3046A) Patient Monitors. The MMs Provides measurement data for Electrocardiogram (ECG)/Arrhythmia/ST, Respiration, Oxygen Saturation (SpO2), Non-invasive Blood Pressure (NBP), and Invasive Pressure or Temperature. Its integrated version of Philips FAST-SpO2 Pulse Oximetry Technology is compatible with all sensors. The MMS sends processed measurement data to the monitor screen, generates alerts, and supports the transfer of patient data between monitors. An MMS Extension can optionally be attached to Multi-Measurement Module to add a combination of the following possible parameters: Mainstream and Side Stream CO2, Invasive Blood Pressure, Temperature and Cardiac Output. M3001A MMS Module with Options A01-A04 / CO6-C18

FORUMSView All (9)
Ask a New Question

0

Replies
-Jack D.
2 years ago
M3001A Module Compatibility
Good morning, I wonder if M3001A MMS module with serial number prefix DE907 is compatible with an IntelliVue MP70 monitor hardware revision B.00.18 and software revision M.03.03. Current compatibility matrix charts I've found don't list the M software revision which is the reason I'm asking here. Thanks, Jack

Equipment: Philips - M3001A MMS Module

Reply

6

Replies
-Tom_m
5 years ago
Compatibility
Good evening, I wonder if there is a compatibility list available for the Philips M3001A mms module. I have a IntelliVue MP30 monitor with hardware A.00.21 and software F.01.43 revisions and what version Of MMS I need to look for. Thanks in advance! TomReply

1

Reply
-Chris S
5 years ago
Asystole Troubleshooting
Here are some troubleshooting steps for when a nurse cannot get a heart rate readout from an ECG waveform, or the monitor continuously alarms for Asystole. 1) Choose the ECG numeric, then find Adjust Size in the pull down. When you do this it may be set to 2x, 3x, or 4x . Increasing size does not help the monitor to analyze the signal. The signal as it is analyzed by the monitor is always at X1. Set the size to X1. This will give you a better picture of what is actually happening . The signal is typically very small size; one the system cannot get a good reading off of. This issue is more likely seen with an e edematous patient or the thin leathery skin elderly type. It is difficult to get a good signal due to the type of skin. 3) Instruct the nurse do a mild dermabrasion. Attempt to clear the skin of oil or loose skin. 4) Ask the nurse to replace the patches. Ensure the patches are within their expiration date, and the package has not been opened for more than 24-48 hours. 5) If the signal is still weak, try switching to single lead analysis. This can be done from the central or bedside. Search through all of the available lead selections for one than has the best and strongest signal. Reply
SERVICE COMPANIESView All Modules Companies

VIDEOS

PAC FAQ: How to Find The Diffe...
PacFaq- How To Locate The Soft...
PAC FAQ: Difference Between Op...

FEATURES

  • Supports the transfer of patient data for fully flexible monitoring
  • Patient demographics, measurements data and trends (for up to the last eight hours at one minute resolution for all numeric), are stored in the MMS, and can be uploaded to a Philips Intellivue or M-Series patient monitor
  • Patients can be transferred by disconnecting the MMS from a host monitor, and then reconnecting it at a new monitor
  • Even while disconnected from a host monitor, the MMS can retain data for patient identification, trends and all active parameter settings for 6 hours
  • The optional MMS extension can extend your measurement capability by offering the following possible channels: Integrated mainstream or side-stream CO2, one additional pressure, pressure/temperature and cardiac output
  • Extends 12-Lead ECG monitoring across the continuum of care. It can be used for ECG monitoring with either standard or EASI electrode placement.
  • Used with the Intellivue family of patient monitors with a 10-electrode lead set for conventional 12-Lead ECG, it provides diagnostic signal quality, as defined in the ANSI/AAMI standard EC11-1991
  • Used in EASI ECG monitoring mode, it provides 12-Lead ECG data using only 5 electrodes, saving set up time, reducing interference with clinical procedures and increasing patient comfort
  • Any number of electrodes between 3 and 10 can be used for ECG monitoring using conventional lead placements
  • Up to 12-Lead ST segment measurement analysis and alarms at the bedside.
  • Multi-lead arrhythmia at the bedside
  • QT/QTc interval monitoring provides the measured QT interval, the calculated heart rate corrected QTc value and a QTC value, which tracks variation in the QT interval in relation to a baseline value
  • Philips FAST-SpO2 pulse oximetry technology is compatible with the full line of Nellcor OxiMax sensors including the MAX-FAST forehead sensor and non-adhesive SoftCare sensors
  • Choice of either auscultatory or intra-arterial measurement reference for Non-Invasive Blood Pressure

SPECIFICATIONS

Weight3 lbs
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree