Abiomed - BVS 5000
by Abiomed

Follow Us
DESCRIPTION
The BVS 5000 is the most widely used mechanical cardiac assist device for patients with a potentially recoverable heart.

The ABIOMED BVS 5000™ is used worldwide for temporary left, right, or biventricular (both ventricles) support in patients with potentially reversible heart failure. The BVS 5000 underwent preclinical studies at the Texas Heart Institute (THI) from 1986 to 1988 and was introduced for use in patients at THI in 1988. It was the first heart assist device approved by the US Food and Drug Administration for the support of post-cardiotomy patients (those who have developed heart failure as a result of heart surgery). Since that time, hundreds of patients have been sustained by the BVS 5000.        [b]The Pump[/b]        The pump houses two polyurethane chambers: an atrial chamber that fills with blood through gravitational force and a ventricular chamber that pumps blood by air-driven power. The atrial chamber is vented outside the patient. The ventricular chamber is connected to the power console by a 0.25-inch pneumatic (air) line. Two trileaflet valves separate the atrial and ventricular chambers. The pump can produce blood flow of up to 5 liters per minute. Cannulas of various designs (for blood drainage and return) are available to accommodate individual patient anatomy.        [b]The Console[/b]        ABIOMED BVS 5000 ConsoleThe BVS 5000 console can support one or two blood pumps. It is fully automatic and compensates for changes both in preload and afterload. The left and right sides are triggered independently of each other. A backup battery provides 1 hour of support, and an alarm will sound when only 10 minutes of power remain. A foot pump can also serve as a backup power source. By using the console to limit blood flow, patients can be slowly weaned from support.

FORUMSView All (1)
Ask a New Question

2

Replies
-Catherine247
10 years ago
inquiring

Requesting details as to instrument reference to "Adiomed BVS 5000".

Reply
DOCUMENTS / MANUALSView All

FEATURES

[list]    [*] Can be supported by all Abiomed Console technology: AB5000™, BVS® 5000, BVS® 5000i, and BVS® 5000t    [*] Off ers LVAD, RVAD, and BiVAD support    [*] Dual-chamber design allows safe, complete ventricular decompression and continuous, passive, gravity assisted drainage of the heart    [*] The BVS® 5000 Blood Pump connects with all Abiomed Cannulas to facilitate “closed chest transition” to the longer-term AB5000™ Ventricle    [*] Design allows pulsatile flow providing both cardiac and systemic perfusion    [*] Improved reimbursement for recovery        Can be used in the following cases:    [*] Donor heart dysfunction or donor heart failure after heart transplantation    [*] Right-sided heart failure after placement of a left ventricular assist device    [*] Acute heart attack    [*] Acute heart disorders, such as viral myocarditis    [*] Trauma to the heart    [*] Disease of the heart muscle (cardiomyopathy)    [*] In patients whose hearts have not recovered after temporary support, the BVS 5000 may be used as a bridge to another device or as a bridge to heart transplantation    [/list]

SPECIFICATIONS

Height33.25 in
Length 22 in
Weight180 lbs
Width24 in

Additional Specifications

Operating Temperature Range: 10°C to 40°C     Operating Humidity Range: 30% to 75% (non-condensing)     Electrical Mains Voltage: Factory configured for operation from either 100 VAC, 120 VAC, 200 VAC, 220 VAC, or 240 VAC.     Mains Frequency: 47 to 63 Hz     Mains Current: 3.6 A maximum at 120 V, 1.8 A maximum at 220 V.     Average power consumption: 280 W