Hitachi Medical Systems - Sirius HP/HT 130
by Hitachi Medical Systems

Follow Us
DESCRIPTION
Easier for the operator to use and also gives a relaxed feeling to examinees.

The human mobile X-ray system, in which “easiness” and “friendliness” are incorporated as results of pursuing high function and operability for smooth examination, is Sirius 130HP.   
asier for the operator to use and also gives a relaxed feeling to examinees.   
Mobility is on of the most important factors for mobile X-ray unit. The unit can be slowly , speedily and smoothly driven through a narrow space, and stopped precisely , providing queit and excellent driving operability.

FORUMSView All (6)
Ask a New Question

0

Replies
-Freddy1971
9 days ago
Error code 3

Hello,

Would you please provide me with service manual or at least the error codes list for :

Hitachi Srius Ubiquitas X-Ray unit

We are having Error 03 as soon as you start the machine.
Thank you so much in advance 

Equipment: Hitachi Srius Ubiquitas Mobile X-ray unit

Reply

0

Replies
-Hussein jalili
3 months ago
error 3

how to solve the error 3

Equipment: Hitachi Medical Systems - Sirius HP/HT 130

Reply

0

Replies
-Ahmad k
2 years ago
Error 06
Hitache siruis 130hp error 6 , and if can i need service manual.Reply
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Mobile Radiography Companies

FEATURES

       
  1. Touch Sensor for Safety - A silent design motor and cushion casters are adopted to stop the system from making a loud noise when travelling. Useful for travel during the night and for shock absorption when going over steps.   
  2. Wide Frontal View - The wide frontal view is ensured even if for a short-heighted operator thanks to not only a slim body design but also eliminated high voltage cable in a mono-tank and a low-mounted X-ray tube assembly.   
  3. Swiveling Mechanism of the X-ray Tube Assembly - Even when the arm is at a tilt, the body axis of the patient and the axis of the x-ray tube assembly can be matched with this mechanism. This is an indispensable mechanism for fine positioning.   
  4. Effective positioning, adjusting the switch - Fine adjustment of the cart positioning is possible using the adjusting switch positioned on the remote panel while carrying out positioning. Contributes to shortening the time necessary for doctor’s rounds.   

Additional Specifications

  • 15kW X-ray generator   
  • X-ray focal spot: 0.6mm   
  • Maximum driving speed: 5km/h   
  • Driving mode: Drive/half/Bedside/Adjustment   
  • Battery power supply system   
  • X-ray tube head supportingsystem: Pantographic arm (HP) or Telescopic Arm (HT)   
  • Storage for 12 cassettes