Olympus - CLV-190
by Olympus

Follow Us
DESCRIPTION

Light Source

With the EVIS EXERA III Xenon Light Source CLV-190, pre-procedure setup has never been easier thanks to a new One-touch Connector for EVIS EXERA III endoscopes. The EVIS EXERA III Xenon Light Source CLV-190 boasts a range of new features designed to improve ergonomics within the endoscopy room. A new waterproof One-touch Connector enables fast and efficient setup without the need for additional cables. A new cooling fan design also helps to reduce background noise levels.     Brighter, more powerful Narrow Band Imaging (NBI) delivers high contrast images of vessel structures, meaning the range of applications for NBI within EVIS EXERA III is increased. EVIS EXERA III Xenon Light Source

FORUMSView All (3)
Ask a New Question

3

Replies
-Michael78
a year ago
Error code
We are having an issue with one of our units. It is displaying the message CLV lamp ERR E103. Please check examination lamp. I have not seen this before. The device is currently in use. It does not seem to be hindering the department from using it. Thank you.Reply

2

Replies
-Stan Skaggs
2 years ago
Lamp Counter Will Not Reset
Hi guys, I put a new lamp in the light supply, and it will not reset like usual.. It seems the indicator lights on the panel are blinking and it seems the light is working as I can see the light in the door.. I defeated the interlocks to see the light ignite as well. I replaced four of these with new bulbs, and all reset just fine.. This one just will not reset for some reason. The lights are all on and blinking for the time meter.. It is a CLV-190 EVIS EXERA III (I realize there are several variants of the CLV-190.. This is what mine are).. Hope you guys might have an idea to look for before I call Olympus tomorrow.. mrstanReply

2

Replies
-Davis Silva
2 years ago
Err300
The light souce gives an error message, Clv scope err E300 connect the scope againReply
DOCUMENTS / MANUALSView All

FEATURES

  • Brighter and higher contrast Narrow Band Imaging - NBI in EVIS EXERA III offers a significantly increased viewable distance compared to previous generations. The improved contrast combined with this increased brightness means that NBI opens new possibilities in assisting you in lesion detection and characterization.
  • Waterproof One-touch Connector - The new one-touch Connector enables a one-step connection to the light source and does not require a separate video cable for connection to the video processor. This saves time during procedure setup and dismantling.
  • Operating noise reduction - A new cooling fan design means that the operating noise level is significantly reduced compared to previous generations.
  • Easy connection of peripherals - A new link connection means that connection of accessories such as ScopeGuide or flushing pumps is easier and faster than ever before.

SPECIFICATIONS

Height150 mm
Length 476 mm
Weight19 kg
Width370 mm
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree