Fluke Biomedical - RaySafe i2
by Fluke Biomedical

Follow Us
DESCRIPTION
Personal dosimeter radiation badge system

Approximately 3.6 billion x-ray examinations are performed worldwide each year, leading to earlier and more accurate diagnosis of medical diseases. However, clinical staff and patients face significant risks of stochastic and deterministic impacts of radiation. Authorized regulatory bodies emphasize the importance of keeping the dose to medical staff and patients as low as reasonably achievable (ALARA).                        The traditional method to provide radiation safety is by offering radiation protection training. The medical staff that works in this very dynamic environment easily overlooks the invisible radiation risk. This can often lead to higher than necessary radiation exposure.                        The RaySafe i2 allows staff to visualize x-ray in real-time. Building a strong radiation safety culture starts with giving the medical staff real-time insight about their personal exposure. This enables and empowers physicians, nurses, and staff to more effectively use all the radiation reduction solutions provided in the room. The RaySafe i2 is an active dosimetry system that provides real-time insights about radiation exposure, helping medical staff and physicians evaluate and directly adjust their behaviors.                        The RaySafe i2 offers ease of use along with quick setup and installation. Similar to many personal electronics, the RaySafe i2 dosimetry system offers touchscreen technology. Personnel wear digitally assigned dosimeter badges and go about performing daily duties without interruption. Dose data is measured and saved for post procedure review and analysis.                        The RaySafe i2 system stores data for up to 5 years, making this system your long term partner in building a first-class radiation safety culture. The dosimeter lasts 3-5 years, dependent on use, and does not require any annual calibration or maintenance. The system is built for rugged use in interventional and vascular labs.

FORUMSView All
Ask a New Question
DOCUMENTS / MANUALSView All

FEATURES

[list]  [*] The active dosimeter measures and records radiation every second  [*] Dose data is transferred wirelessly to the real-time display  [*] By tapping the dosimeter name on the touch screen you can access more detailed information about the personal dose history  [/list]

SPECIFICATIONS

Height60 mm (display)
Length 250 mm (display)
Weight1240 g (display)
Analyzer/Simulator TypeRadiation Dosimeter
Width300 mm (display)

Additional Specifications

Display Resolution: 640 x 480 pixels            Dosimeter Weight: 30 g            Dosimeter Operational Quantity: Hp(10)            X-ray dose range: 1 ΜSv – 10 Sv

NEWSView All
New Updated PTB Certificate for RaySafe X2

New Updated PTB Certificate for RaySafe X2

RaySafe, the global leader of X-ray quality assurance solutions, has received a new updated PTB approval for RaySafe X2.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree