Advertisement

Nova Biomedical - StatStrip Xpress
Manufactured by Nova Biomedical

DESCRIPTION
StatStrip provides the analytical performance for those testing situations where glucose meter interface capability is not needed.

The introduction of StatStrip Xpress provides hospitals a choice of glucose monitors with or without a connectivity solution using the same Multi-Well test strip.  
Like the StatStrip™ Glucose Hospital Meter, StatStrip Xpress elevates bedside glucose testing to a new level of analytical performance that approaches the quality of central laboratory testing.It incorporates a new strip technology that uses four measuring wells.Nova’s Multi-Well system measures and corrects hematocrit interference, as well as interferences from acetaminophen (Tylenol), uric acid, ascorbic acid (Vitamin C).StatStrip Xpress also eliminates oxygen, maltose, galactose, and xylose interferences.Freedom from interferences, coupled with excellent correlation to central laboratory reference methods, provides improved accuracy compared to conventional meters and strips.  
 
StatStrip Xpress’ 6-second analysis time, small 1.2 microliter sample size, and simple operating steps make bedside glucose testing fast and easy.Unlike competitive glucose analyzers, StatStrip Xpress requires no calibration codes.This eliminates a potential error source, reduces the number of steps required for testing, and allows StatStrip Xpress manufacturing lots to be used interchangeably.

QUESTIONS & ANSWERSView All

0

Answers
-M.mahrous
7 months ago
Purchase
I want to purchase one for medical researchReply

0

Answers
-dcarlantonio
10 months ago
Date Change
How can the date be changed on the Stat Strip Xpress monitor? We just realized that the date is a day behind. Possibly due to leap year? There are no instructions as to how to change it. Thank you for any assistance you can provide.Reply

0

Answers
-Linda Mc
a year ago
Medical Assistant
We perform POC glucose testing with your instrument in our office and have been informed that we must report a reference range with each result. Is there a reportablereference range for this instrument? Linda Reply
PREVENTIVE MAINTENANCEView All
Be the first to submit a preventive maintenance post about this equipment

FEATURES

     
  1. LCD black/white display  
  2. Large numeric display (30 mm)  
  3. Traditional QC with target values assigned to QC materials  
  4. Units of measure based on meter ordered (mg/dl or mmol/L models)  
  5. Auto-shut off of meter when not in use  
  6. Automatic sample detection and analysis start  
  7. Automatic sample counter with date/time stamp for data tracking 

Advertisement

Ask a Question

Ask anything about
Nova Biomedical - StatStrip Xpress
Advertisement

For questions about using the MedWrench web site:

(866) 989-7057TOLL FREE  •  (770) 692-8371INTERNATIONAL

support@medwrench.com

MedWrench is in association with:

TechNationMedical DealerOR TodayMD Expo


Testimonials  •  Advertising  •  Privacy Policy  •  Terms and Conditions

© 2017 MedWrench, LLC. All Rights Reserved

Advertisement