Siemens Healthineers - SOMATOM X.ceed
by Siemens Healthineers

Follow Us
DESCRIPTION

Single Source CT Scanner 

SOMATOM X.ceed is a high-resolution, high-speed, low-dose CT scanner with the category-best imaging chain. With the unique guidance of myExam Companion and myNeedle Companion it enables excellent clinical decisions in the most challenging clinical situations – and elite performance of CT and personnel. Find out how you can expand precision medicine and improve patient experience with SOMATOM X.ceed.

FORUMSView All
Ask a New Question
SERVICE COMPANIESView All CT Scanner Companies

FEATURES

  • Intelligent navigation for enhanced consistency. No matter the user, patient, or throughput, our Companions guide users through even time-critical procedures, including emergencies and CT interventions. This helps them interact easily, naturally, and precisely with both patient and technology.
  • Patient-friendly design with an 82 cm bore.A more natural communication with patients and our Mobile Workflow help patients relax and ease tension or anxiety – in combination with the large bore and enhanced accessibility of the new multi-purpose table.
  • Consistent standards across your institution. myExam Companion, myNeedle Companion, and Shui® – the design system of Siemens Healthineers – provide users with common interfaces across multiple modalities. Combined with our digital solutions, they can help you redefine and standardize protocols across your institution, optimizing clinical workflow, staffing schedules, results, and productivity.
  • Elite performance from door to diagnosis. While most CT systems excel in power, scan speed, spatial resolution, or temporal resolution, they compromise at least one of the other metrics. SOMATOM X.ceed benchmarks the category with an optimal combination of high temporal and spatial resolution, power, and scan speed designed to master the most challenging clinical situations at low dose. myExam Companion offers radiology teams automated guidance throughout. The result? Elite performance of both CT and personnel.

Additional Specifications

  • Detector StellarInfinity detector
  • Number of acquired slices 128
  • Spatial resolution UHR Mode: 0.4 mm reconstructions (31.1 lp/cm in x/y direction; 23 lp/cm in z direction; +/-10% at 2% MTF)
  • Rotation time down to 0.25 s
  • Native temporal resolution down to 125 ms 
  • Generator power 120 kW
  • Max. scan speed 261 mm/s
  • Max. mA (70, 80, 90 kV) 1,300 mA
  • Gantry opening 82 cm
  • Gantry cooling Water/Air
  • Table load 307 kg / 676 lbs
  • Installation space One room concept < 17 m2 / 183 ft2 (Subject to local regulations. Safety distances must be checked according to country-specific requirements.)


This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.