GE HealthCare - SAM
by GE HealthCare

Follow Us
DESCRIPTION

Modules

The GE SAM (Smart Anesthesia Multi-Gas) Module provides an analysis of respiratory and anesthetic gases when used in conjunction with the GE patient monitors. This compact module provides CO2 waveforms and automatically identifies anesthetic agents and quantification. This module is pre-owned & in excellent condition.

FORUMSView All (4)
Ask a New Question

0

Replies
-U.V. vaishnav
Tue Mar 12 2024
NEED SERVICE MANUAL OF GE SAM 80 AGME GAS MODULE

I WANT TO SERVICE MANUAL OF GE SAM 80 GAS MODULE.

I AM FACINEG THE ERROR OF SERVICE MODULE AND CHECK SAMPLE LINE.

Reply

0

Replies
-U.V. vaishnav
Tue Mar 12 2024
NEED SERVICE MANUAL OF GE SAM 80 AGME GAS MODULE

I WANT TO SERVICE MANUAL OF GE SAM 80 GAS MODULE.

I AM FACINEG THE ERROR OF SERVICE MODULE AND CHECK SAMPLE LINE.

Reply

0

Replies
-U.V. vaishnav
Tue Mar 12 2024
NEED SERVICE MANUAL OF GE SAM 80 AGME GAS MODULE

I WANT TO SERVICE MANUAL OF GE SAM 80 GAS MODULE.

I AM FACINEG THE ERROR OF SERVICE MODULE AND CHECK SAMPLE LINE.

Reply
SERVICE COMPANIESView All Modules Companies

FEATURES

  • Display of CO2 waveform
  • Inspired and expired digital gas
  • Respiratory rate
  • Integrated alarms
  • Graphics and Tabular Trend Values

Additional Specifications

Dimensions

  • Height: 3.15 in (8 cm)
  • Depth: 10.625 in (27cm)
  • Width: 4.4in (11.2 cm)
  • Weight: 6 lb (2.70 kg)

Information Displayed

  • CO2 concentration in %, mmHg or kPa;
  • N2O concentration in %, mmHg or kPa;
  • O2 concentration in %, mmHg or kPa*;
  • Agent concentration in %, mmHg or kPa;
  • Respiratory rate; • Continuous CO2 waveform;
  • Continuous O2 waveform*

Measurement Range

  • CO2: 0 to 10%; N2O, O2*: 0 to 100%; Isoflurane, Halothane, Enflurane, Sevoflurane: 0 to 7%, Desflurane: 0 to 20%

Accuracy

  • O2: ± 2% Abs.*; N2O: ± 5% Abs.;
  • CO2, Halothane, Enflurane, Isoflurane, Desflurane, Sevoflurane: ± 0.2% Abs. or ± 5% of reading, whichever is greater; Detection threshold of the second anesthetic agent in a mixture: 0.3% of agent gas;
  • Trends: All gas values & respiratory rate, for up to 24 hours, Sampling: Sidestream;
  • Technology: Infrared for CO2, N2O, agents; Paramagnetic for O2*;
  • Water Trap: Disposable hydrophilic Aqua-Knot II water trap with automatic shutoff and on-screen indicator;
  • Flow rate: 250 ml/min (nominal) 150 ml/min (no O2)*

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree