Beckman Coulter - Ac·T 5diff AL
by Beckman Coulter

Follow Us
DESCRIPTION

Hematology Analyzer 

The Ac·T 5diff AL improves sample handling by eliminating manual sample loading, which also saves time, lowers operational costs and increases your labs overall workflow efficiency. Also included is an easy-to-use data management system that streamlines data recall and requires less manual manipulation.

FORUMSView All (8)
Ask a New Question

1

Reply
-elab
7 years ago
BATH DRAIN SENSOR P/N XBA395AS
Can anyone assist me on finding this part for this instrument pls....beckman coulter act diff 5 bath drain sensorReply

1

Reply
-elab
8 years ago
ERRORmessages : how do we clear of this error,ERRORmessages : how do we clear of this error
error messages was: 1 ) Miscelaneous Message COM error on Slave 18 2 ) Miscelaneous Message MOTOR 9 is active,error messages was: 1 ) Miscelaneous Message COM error on Slave 18 2 ) Miscelaneous Message MOTOR 9 is activeReply

1

Reply
-imco70
9 years ago
error message

Hey Guys , any idea for the following error message

 

motor 7 is active 

 

thanks in advance 

Reply
DOCUMENTS / MANUALSView All

FEATURES

  • Closed vial sampling that accommodates a variety of collection of tube sizes
  • Small 18 uL sample size in either closed or open vial modes
  • User-definable high/low flagging of patient results and quality control simplifies data interpretation
  • Automated quality assurance functions improve productivity
  • Closed vial sampling for controls and calibrators provides operator safety
  • Compact benchtop design requires only two square feet of counter space
  • Zero routine maintenance and high system reliability help contain costs

Additional Specifications

  • ACT 5Diff AL, checked, tested, calibrated, working condition.
  • The AcT 5 diff AL is fully automated bench - top 5 - part differential hematology analyzer with automatic loading and sampling.
  • The Ac·T 5diff AL improves sample handling by eliminating manual sample loading, which also saves time, lowers operational costs and increases your lab’s overall workflow efficiency. Also included is an easy - to - use data management system that streamlines data recall and requires less manual manipulation.

NEWSView All

Device Alert

Beckman Coulter—COULTER AC•T 5diff Hematology Analyzers: Valves May Fail Prematurely, Potentially Leading to Erroneous Results, Increased Instrument Errors, and/or Fluid Leaks See attached PDF under Manuals & Resources tab