Hitachi Medical Systems - Echelon
by Hitachi Medical Systems

Follow Us
DESCRIPTION

Hitachi’s Echelon 1.5T provides outstanding imaging performance today and is the basis for high performance far into the future.

Echelon’s high performance 1.5T magnet, ultra fast 150T/m/sec slew rate gradient system, 8 channel RF receiver (with a 16-channel XLS option), and wide range of multi-channel receiver coils provide unmatched value as a data acquisition platform.

FORUMSView All (4)
Ask a New Question

1

Reply
-Yurok.inc
4 years ago
MRI 1.5T

need a service and user manual for MRI Hitachi Echelon Oval 1.5 T

Reply

3

Replies
-eng.halim
10 years ago
service manual

want service manual for CT Scan machine

Reply

0

Replies
-MedWrenchManager
13 years ago
Echelon XL imaging suite
Hitachi’s Echelon XL clinical and vascular imaging suites provide sequences, tools and features such as RADAR radial acquisition and Fluoro triggered bolus MRA. Tools include MIP, MPR, vascular volume rendering, dynamic analysis and ADC and isotropic DWI analysis. ORIGIN MR operating software incorporates a graphical user interface, and the layout intuitively guides the operator from patient registration through image archiving. An integrated image quality calculator informs the technologist of the impact parameter changes will have upon the image. Intelligent parameter guidance displays options to begin scanning. Echelon's magnet delivers high homogeneity, and the standard per patient higher order active shim enables optimized general image quality and uniform RF fat saturation, the company says. It has a weight limit of 500 pounds and a 61-centimeter bore, and the table has more than nine feet of table travel and lowers to 19.5 inches. Echelon's computer system integrates a multiprocessor CPU and an advanced scan/reconstruction engine. [url=http://www.medicaldealer.com/article.aspx?Id=1113]Originally published in MedicalDealer Magazine.[/url]Reply
SERVICE COMPANIESView All MRI Systems Companies

FEATURES

  • Clinical Suite 
  • SE, IR, FSE, FIR, DE-FSE, DE-FIR [*] GE, SG, BASG, RSSG
  • DWI 
  • RADAR radial acquisition 
  • RAPID Parallel Imaging 
  • Water Excitation
  • Regional Shim
  • Vascular Suite 
  • TOF
  • FLUTE Fluoro-triggered bolus MRA 
  • TRAQ Time-resolved MRA
  • VASC Non-contrast MRA 
  • Tools 
  • MIP
  • MPR
  • Vascular volume rendering
  • Dynamic analysis
  • ADC and isotropic DWI analysis 
  • ORIGIN MR operating software 
  • Rapid registration mode 
  • Drag-and-drop patient directory management
  • Anatomically-grouped protocol lists
  • Easy-to-save site specific protocols
  • Hitachi-recommended protocols 
  • Magnet, Gantry and Patient Amenities
  • 1.6 meter gantry
  • 61 cm bore
  • Up to 500 lbs weight limit
  • Over 9 feet of longitudinal table travel

SPECIFICATIONS

Weight5150 lbs
Clinical UseWhole Body
Gantry (Max. Clearance) 61 cm
Magnetic Field Strength1.5 T
Patient Weight Capacity500 lbs
NEWSView All

Echelon XL imaging suite

Hitachi’s Echelon XL clinical and vascular imaging suites provide sequences, tools and features such as RADAR radial acquisition and Fluoro triggered bolus MRA. Tools include MIP, MPR, vascular volume rendering, dynamic analysis and ADC and isotropic DWI analysis. ORIGIN MR operating software incorporates a graphical user interface, and the layout ...

Product Focus Radiology Market Analysis Magnetic Resonance...

by: John Buie via MD Publishing Since its introduction, Magnetic Resonance Imaging (MRI) has become a ubiquitous diagnostic tool. It now represents one of the most rapidly expanding sectors in the medical imaging market. It has been claimed that all medical imaging segments are on the cusp of a major new phase of growth. This imminent ...

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.