Thermo Scientific - HERAEUS Cryofuge 5500i
DESCRIPTION
Refrigerated Blood Processing Floor Model Centrifuge.Developed to meet the needs of users in a wide range of environments - including hospital blood banks and laboratories, satellite blood processing centers, and clinical reference labs - the versatile floor model Cryofuge® 5500i provides exceptional processing power for a host of applications. With the Cryofuge 5500i, spin four blood bags – from doubles to 500 ml quads – reliably and reproducibly. In addition, realize the benefit of greater throughput from higher g-forces and capacities for all popular types of blood collection and clinical tubes. Minimize sample handling steps by spinning clinical analyzer racks already pre-loaded with tubes. In keeping with the latest trends in clinical testing, the Cryofuge 5500i maximizes microplate processing with the added benefit of biocontainment. A wide range of rotors, including windshielded swinging bucket, clinical analyzer rack and windshielded microplate varieties, offers maximum flexibility for blood component processing and clinical testing needs.
FORUMSView All (4)
1Reply11 years ago | Error E-27 The refrigerated centrifuge Model Cryofuge 5500i displays an Error E-27 and the instrument is not starting. Could you please help me in troubleshooting or please provide me the service manual? Reply |
0Replies12 years ago | question for Cryofuge 6000i run time calculation what is the different profile wise time duration for different acceleration profile & deceleration profiles 1-9? we want to calculate the total run time. Kindly helpin explaning this in case the graphical description can be given,it will be more helpful Reply |
1Reply13 years ago | main switch connections how to fix main switch connectionsReply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Centrifuge Companies
FEATURES
[list] [*] Large four liter or blood bag capacity [*] New Diagnostik™ rotor spins clinical analyzer racks pre-loaded with tubes. [*] Higher g’s and capacities for all popular blood/clinical tubes than leading competitors [*] Superior 32 standard microplate capacity [*] HIGHplate® rotor spins microplates, or filter plates to 85 mm in height, at 5,890 x g [*] Reduced maintenance with brushless induction drive [/list]
Height | 960 mm |
Length | 720 mm |
Weight | 286 kg |
Width | 680 mm |
Additional Specifications
[list] Drive: brushless induction drive Accel./decel. profiles: 9/9 Program memory: 9 + 1 pretemp program Temperature range (°C): -9 to +40, CFC-free refrigerant Control: microprocessor controlled via EASYcontrol™ II Functions: RCF-preselection, Quick-run, automatic rotor recognition, imbalance detection and Soft-Touch lid-lock Imbalance: electronic, speed and rotor dependent Test standards: Designed and tested in accordance with EN 61 010-1, EN 61010-2-020, EN 50 081-1, EN 50 082-1 [/list]