Esco Technologies - HPI-4N3
by Esco Technologies

Follow Us
DESCRIPTION
Isoclean Hospital Pharmacy Isolator (Negative Pressure, Recirculating)

Esco Hospital Pharmacy Isolators, Negative Pressure, Recirculating Models, provide a safe and clean environment for compounding of hazardous, sterile drug preparations in compliance with USP 797 criteria.      Barrier isolation system provide inherently superior sterility compared to open front clean air devices such as laminar flow clean benches and Class II biological safety cabinets. USP797 guidelines specify that isolators may be situated in an area subject to less severe environmental controls compared with open front clean air devices.      When used as part of a system that includes operator aseptic technique training, process validation, expiration setting, product quality maintenance after the CSP leaves the pharmacy, isolators are a cost-effective solution especially for lower-volume pharmacies. They reduce operating and renovation costs, take up less space, and are easier to maintain.      The negative pressure, recirculating HPI model is suitable for work involving hazardous materials, antineoplastic, or cytotoxic compounding applications. The work zone and pass-thru interchange are under negative pressure to the room in order to maintain operator protection in case of a breach in the barrier isolation system.

FORUMSView All
Ask a New Question

FEATURES

[list]   [*] ULPA filters with a typical efficiency of 99.999% at 0.1 to 0.3 microns provide superior ISO Class 3 air cleanliness, 100 times better than competing products.   [*] Sentinel Gold™ Microprocessor controller supervises all functions and monitors airflow and pressures in real-time.   [*] Work zone and pass-thru are under negative pressure to the room in order to maintain operator protection in case of a breach in the barrier isolation system.   [*] Robust dual-wall construction. The work zone is surrounded by negative pressure plenums at the sides and back. Unique Esco Dynamic Chamber™ plenum surrounds filter seals with negative pressure.   [*] Ergonomically angled front and oval gloveports improve reach and comfort.   [*] Safe-change cuff rings permit glove changes with zero risk of contaminating the work zone or pharmacy environment.   [*] One piece work zone liner with no crevices is easy to clean.   [*] Esco ISOCIDE antimicrobial coating on all painted surfaces minimizes contamination.   [*] Sharps disposal system and hydraulic height-adjustable stand are available as options.   [/list]

SPECIFICATIONS

Height1995 mm
Length 820 mm
Width1522 mm

Additional Specifications

InternalDimensions (mm): 840 W x 610 L x 670 H  Airflow Velocity (Downflow): 0.20(m/s)/40fpm(fpm)  Electrical: 220-240V,AC, 50Hz,1ø

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree