Axon Systems - Eclipse
by Axon Systems

Follow Us
DESCRIPTION
More information for more informed decisions.

Eclipse Neurological Workstations provide comprehensive neurological monitoring in the operating room and intensive care unit to accurately access your patient’s neurological status.              Axon Systems’ neurological monitoring systems have a proven record of accurate and reliable performance. And now the Eclipse with 32 channels, transcranial Doppler, built-in fast charge, high output, transcranial electrical motor evoked potential (TCeMEP) stimulation, pulse oximeter and dual synchronized video recording and playback provide the missing elements to complete the neurological evaluation. 

FORUMSView All (4)
Ask a New Question

0

Replies
-Neuro
8 years ago
Linda Chapa president of a neurodiognistic company

Does this Eclipse include recording box, and stimulation box? Also the cables?

Reply

0

Replies
-Kamal Raj
9 years ago
NIM-ECLIPSE: Unable to get calibration signal on the right side of the screen

NIM-ECLIPSE

I am having trouble in NIM-ECLIPSE neurophysiology supported software, under calibration section: Unable to get the calibration signal on the right side, but on the left side I am getting proper calibration signal/output.

When I use this NIM-ECLIPSE neurophysiology supported software for monitoring, I am getting good bilateral EP (SEP) response /recording.

I would like to know that anyone had this kind of calibration output/response; also I would like to know that it is still okay to use the equipment for monitoring.

 

Reply

3

Replies
-Chris Dobbs, CNIM
10 years ago
Seeking an Axon NIM Eclipse IOM System

I am currently looking to obtain a used Axon NIM Eclipse IOM machine for mobile use in multiple operating rooms. I do not need a laptop as long as the system comes with an software installation disc

 

Reply
DOCUMENTS / MANUALSView All

FEATURES

[list]      [*] Transcranial Doppler modality - Synchronous TCD and neurological recording and playback      [*] Simultaneous 32 channel EP, EMG and EEG monitoring – Simultaneously assess multiple at risk structures      [*] Import and trend vital signs – Compare systemic measures with neurological data      [*] Dual synchronized video recording and playback. Display the surgeon’s microscope and OR view – Correlate neurological responses with surgical manipulations      [*] Built-in fast charge (1000V @ 1 Amp) TCeMEP stimulation mode with double train – Test motor function without the need for costly, external stimulators      [*] Two built in pulse oximeters - Monitor for leg ishemia. Display and trend oxygen saturation and heart rate      [*] Automated pedicle screw integrity mode - speeds testing of pedicle screw postioning.      [*] Simultaneous multiple site remote monitoring and review – Monitor and review remotely via network, internet or modem.      [*] Resume monitoring on power or system failure with no data loss – Recover data after system or power failure.      [*] Remote monitoring - View multiple OR sites in real-time      [*] Comprehensive summary report - Include screen snapnots, markers tabl es and comments      [*] Laptop portable or stationary platforms – For portable or fixed location requirements      [/list]

SPECIFICATIONS

Frequency Range0.2 to 4000 Hz
Input32 per Digital Preamplifier
Channels8, 16 or 32 (2 Digital Preamplifiers)
Noise20 nV/ root Hz, 100dB @ 10Hz

Additional Specifications

[u]Transcranial Doppler:[/u]        Sweep Time: 3 - 60 seconds        Velocity: 2 MHz PW 800, 400, 200, 100 and 50 cm/s       Traces: Up to 64         Trace display: Current sweep, building average, last average, odd/even averages, up to 3 replications and baselines per trace, average of last 3 replications.    Baselines: Installed independently by trace  Markers: Up to 8 per trace. Manual and automatic placement.        [u]EMG MONITORING[/u]        Traces: Up to 64        Collection: Continuous, free running and signal and/or stimulus triggered.       Audio output: Selectable; any or all EMG channels.       Signal trigger tones: Unique frequency tone identifies highest amplitude signal trigger trace.        Muting: Automatic muting of electrocautery noise using Mute Probe or dedicated Mute Trace.       [u]STIMULATION GENERAL[/u]        Modes: Repetitive, non-repetitive        Interleaving: Up to 16 stimuli       Stimulus rate: 0.01 – 100 stim/sec        Train rate: 1 – 500 Hz       Train count: 2 – 200       Operating system: Windows XP       Platform: Desktop or Laptop Portable        Graphics resolution: Min 1024 X 768        Display size:        Desktop: 15”, 17”, 19” or 21”       Portable: 15” min TFT LCD display       Electrical:        EN13485, UL2601, IEC 601-1, NRTL, CSA, CE.