Sysmex - XT-2000i
DESCRIPTION
Hematology Analyzer
Reliable detection of abnormal samples remains the most important issue in the hematology laboratory. Accurate WBC, RBC, PLT and Differential results are essential to providing meaningful clinical information and in maintaining an efficient laboratory. However, traditional techniques are often inadequate when it comes to analyzing critically ill patients samples. The xt-Series, which is comprised of the xt-2000i and the xt-1800i, use the identical, advanced, patented Fluorescent Flow Cytometrytm technology and state-of-the-art cell counting methods. The xt-Series extensive panel of hematology parameters provides more comprehensive data for better clinical decisions.
Traditionally, only high-volume laboratories could afford full automation. The compact xt-Series analyzers allow any size lab the opportunity to enjoy the benefits of state-of-the-art Fluorescent Flow Technology and automation, making these analyzers ideal as both a primary system and as a secondary system to the xe-2100 analyzer. At a rate of 80 samples/hour, the xt- Series streamlines your labs workflow by providing fluorescent enhanced traditional CBC parameters and sensitive flagging algorithms that make the assessment of abnormal samples routine.
FORUMSView All (14)
0Replies2 years ago | How to perform QC on sysmex XT 2000i hematology analyzer,? I forgot the process of performing the QC on sysmex XT 2000 I anlyzer plz tell me the procedure.Reply |
0Replies3 years ago | Inverting neut# and Lymph # or no # at all Inverting the neut #s and Lymph #s on the diff portion of the analyzer report about 50-60% of the time. The other 25% if the time it gives no diff #s at all. Samples checked for clots and enough sample. Reply |
2Replies4 years ago | Looking for Fluidics flow diagram for Sysmex XT2000i Hello, need Flow diagram on a XT2000i Hematology Analyzer Also looking for a Operators manual and Guide for XT2000i Thank You Don Byrd Hollinger DiagnosticsReply |
DOCUMENTS / MANUALSView All
FEATURES
- Fluorescent enhanced WBC Differential Counts
- Fluorescent and Impendence Platelet Counts
- Fluorescent Reticulocytes and Immature Reticulocyte Fractions(IRF)
- Lot-to-Date Reports are available immediately anytime you upload data
- 2 Period Reports (approx. 28 days each)
- Cumulative Report (combined statistics for Periods 1&2)
Additional Specifications
- Data storage- 10,000 samples (incl. graphics)5,000 patients’ information 1,000 selective test orders
- Dimension and weight - 530x630x720/59 (main unit with sampler)280x400x355/17 (pneumatic unit) 305x85x345/8 (IPU: information-processing unit)