Ortho Clinical Diagnostics - VITROS 350
DESCRIPTION
A compact chemistry system designed to be efficient, dependable, and above all, easy to use as a primary, STAT, or backup system.The VITROS 350 Chemistry System offers easy operation, maintenance, and training. Whether users use it as a primary, STAT, or back-up to the powerful VITROS 5,1 FS, the VITROS 350 Chemistry System will get the job done right the first time. Users know that VITROS Systems are efficient, dependable, and easy-to-use. The VITROS 350 comes complete with enhanced throughput, a broad accessible menu, and new ergonomic design. Boosts productivity and reduce costs with the system that delivers the right results the first time.
FORUMSView All (29)
0Replies10 months ago | Changing Reflectometer Changing reflectometer on vitros350 Reply |
0Replies10 months ago | Rate lamp How do I change rate lamp Reply |
1Reply2 years ago | Urgent Please tell me how to turn on this machineReply |
DOCUMENTS / MANUALSView All
FEATURES
- The VITROS 350 doesn’t require highly-trained operators—simple procedures allow around-the-clock availability to all members of the lab staff
- Easy to train and cross train operators
- Walk-away operation
- Quality control procedures are required just once each day and calibration intervals up to 6 months
- Ergonomically designed, flat low-glare LCD touch screen monitor
- Keyboard platform and support arm
- Flexible, customized positioning
- On-board documentation and help function
- Up to 300 results per hour
- On-board capacity for all 45 assays
- Primary tube sampling
- On-board dilution
- Flexible processing for manual, stat or automated testing
- Unique sample processing capabilities like disposable tips, bubble and clot detection assure confidence in results
- Self-monitoring alerts operators to prompt action, avoiding testing delays
- No plumbing, drains, vents, deionized water is required; all “waste” is contained in used test slides which are disposed daily
Sample Capacity | 40 (4 trays of 10 samples) |
Throughput | 3600 samples/hr |
Sample Types | Serum, Plasma, Urine, CSF |
Sample Volume | 5 to 11 µL |
Additional Specifications
[list] Potentiometric Reaction Time: ~ 2.5 minutes Colormetric Reaction Time: ~ 5 minutes Immuno-rate Reaction Time: ~ 8 minutes Sample Management: Clot Detection, Bubble Detection, Liquid Level-Sensing (Pressure Transducer), Short-Sample Detection Calibration: Extended; multiple lots supported [/list]
NEWSView All
Device Alert
Problem: In a February 4, 2011, Urgent Field Safety Notice letter posted by the U.K. Medicines and Healthcare Products Regulatory Agency (MHRA), Ortho-Clinical Diagnostics (OCD) states that it has received reports in which users observed increased signal-to-cutoff (S/C) ratios for negative patient and quality control samples when using the above re...