Siemens - Dimension Vista 500
by Siemens

Follow Us
DESCRIPTION
Customer-driven design and ultra-integration of four technologies come together to create a system that will revolutionize the way the lab functions.

FORUMSView All (7)
Ask a New Question

0

Replies
-Laboratory Manager
4 years ago
Loading samples verses aliquoting into short sample cups
Does anyone have the visual card that shows the acceptable volume of sample required as a reference? Something like this was provided during the install but it has now gone missing. Any assistance would be appreciated.Reply

1

Reply
-tanisbel
6 years ago
manual
i would like to study the operator manualReply

1

Reply
-ThomasB
7 years ago
no results sent

our V500 is receiving the test requests okbut, we're not seeing any results over the interface. It worked when the rep was here but not since.

Reply
DOCUMENTS / MANUALSView All

FEATURES

  • Processes more than 100 methods simultaneously 
  • 144 onboard reagent slots 
  • Over 90% of typical lab test processed on a single platform 
  • Disease state management from a single primary sample container 
  • Capacity for 600-800 samples onboard simultaneously
  • Processes up to 1000 tests per hour 
  • Common reagent area and packaging
  • High sensitivity immunoassays integrated with best-in-class TAT 
    • 10-minute cardiac 
    • 16-minute 3rd generation TSH
    • 21-minute B12/Folate 
  • The advanced homogeneous chemiluminescent technology 
  • No wash or separation steps 
  • Low sample volumes 
  • Unlimited menu potential
  • Consolidated testing
  • Ease of use 

Automation Onboard eliminates manual tasks

  • EasyLink intelligent device management automatically monitors real-time system performance remotely
  • Automated hands-off calibration and QC
  • Auto-sensitivity, precision and linearity
  • Customizable QC and calibration auto-acceptance parameters
  • Continual monitoring of onboard inventory
  • Auto-verification of results performed according to user-programmable rules
  • Automatic repeat of panic values to ensure result reliability
  • Dual sample clot-check; short-sample detect; sample quality management; sample integrity; HIL 
  • Onboard help system
  • Onboard water purification module

SPECIFICATIONS

Height204 cm (with cover open)
Length 111.5 cm
Weight1856 lbs
Width215.3 cm

Additional Specifications

[list]      Operating Temperature: 64.4-77.0° F (18-25° C) with maximum fluctuation of 5° F (2.8° C) per hour              Relative Humidity: 20-80%              Avg Noise Output: 64 dBA at normal operator position              Thermal Output: 13,000-13,500 BTU/hr      [/list]

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.