The Advisor Vital Signs Monitor offers flexibility in multi-parameter monitoring. Core parameters and a host of options allow the monitor to be tailored to patients' needs, neonate to adult.      Combine the intuitive interface, integrated carrying handle and high-resolution display with the optional rechargeable battery and dual trace printer to create a highly versatile monitoring solution.

FORUMSView All (3)
Ask a New Question

1

Reply
-Joseangel86
11 years ago
Smiths Medical Advisor Monitor NIBP Section

I wonder if someone of you have stock for Advisors Spare Parts, specially I am looking for the whole NIBP section, I mean Valves, pump and electronic board. Thanks in advance for your help.

Reply

0

Replies
-Joseangel86
11 years ago
Smiths Medical Advisor Monitor NIBP Section

I wonder if someone of you have stock for Advisors Spare Parts, specially I am looking for the whole NIBP section, I mean Valves, pump and electronic board. Thanks in advance for your help.

Reply

2

Replies
-MedWrenchManager
14 years ago
Service Manual
I'm looking for a copy of the Smiths Medical/BCI Advisor vital signs monitor service manual. Originally asked by Anthony on Technation listserve.Reply
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Vital Signs/Multi-Parameter Companies

FEATURES

[list]   [*] Basic parameters include 3-lead ECG, respiration, NIBP and SpO2   [*] Optional parameters of 5-lead ECG, invasive pressure/temperature and capnography   [*] 10-inch color display   [/list]

Additional Specifications

[u]Displays & Controls[/u]      Main Display   10.4" high-resolution active matrix color LCD   Resolution = 640 x 480 pixels   Function Keys   ON/OFF, BP Zero All, NIBP start/stop, PRINT   start/stop, Alarm Silence, rotary encoded   push-button control knob      [u]Indicators[/u]   AC Power   Green LED w/power plug icon   Battery Power   Green LED w/battery icon      [u]SPO2[/u]   Range   0-100% (functional saturation)   Accuracy   ±2% @ 70-100% < 70% unspecified   Alarm Range   50-100% and OFF   Averaging   4, 8, 16 pulse beat average      [u]Pulse Rate (SpO2) or Heart Rate (ECG)[/u]   Range   30-250 bpm (SpO2) 30-300 bpm (ECG)   30-180 bpm (NIBP) 30-300 bpm (IBP-ART)   Accuracy   ±2 bpm or ±2% (whichever is greater)   Alarm Range   30–250 bpm and OFF   Averaging   Fixed at 8 seconds      [u]ECG[/u]   Configuration   3-lead (standard) or 5-lead (optional)   Lead Selection   I, II, III, aVL, aVR, aVF and V   Display Gain   x1/2, x1, x2, x4   Defibrillation Protection   Yes   Pace Detect/Reject   Yes   Sweep Speed   25 mm/sec