American Imex - Interspec IF II
by American Imex

Follow Us
DESCRIPTION

Interferential and neuromuscular stimulation device.

Interspec IF-II™     Interferential / Neuromuscular Stimulator          The Interspec IF-II is a digital interferential device that provides 6 interferential programs and a neuromuscular stimulation program. The Interspec IF-II features a post-op program with a continuous treatment timer for constant stimulation following surgery. The device has a patient lock out feature and preset programs for ease of setup. Once the programs are set, the patient then only has to turn on the power and increase the amplitude for treatment. The device will automatically shut off after the treatment cycle has been completed. Five preset interferential programs include a signal vector rotation program. A fully customizable program is also available.        [i]*This item in not for resell in the US*[/i]

FORUMSView All (1)
Ask a New Question

1

Reply
-Cynthia Collins 1
2 years ago
Replace a unit
What is the cost for this unit? Reply
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Electrotherapy Companies

FEATURES

  • Dual Channel Interferential /Neuromuscular Combo Stimulator
  • Post-Op Program Mode with Continuous Use Timer 
  • AC Adapter 
  • Battery, Electrodes, Safety Lead wires, Carry Case

SPECIFICATIONS

Interferential CurrentYES
Neuromuscular Electrical Stimulation (NMES)YES

Additional Specifications

Channel: Dual Channel Interferential and Neuromuscular Stimulation     Wave form: Symmetrical Square Wave     Output: Adjustable 0-60mA peak into 500 Ω load each channel     Carrier Frequency: Channel 1: 4000Hz fixed     Modulating Frequency: Channel 2: 4010-4400 Hz Adjustable     Power Source: 9 Volt AC adaptor or Alkaline Battery          Program 1 Interferential High/Low     Part 1: 100 Hz, Mode 6/6 Ramp, Time 20 Minutes     Part 2: 20 Hz, Mode 6/6 Ramp, Time 20 Minutes          Program 2 Interferential High     100 Hz, Mode 6/6 Ramp, Time 20 Minutes          Program 3 Interferential High Continuous     100 Hz, Time Continuous          Program 4 Neuromuscular     NMES 70 Hz, 2 secs Ramp Up, 6 secs On Time, 12 secs Off          Time, Time 10 Minutes          Program 5 Interferential/ NMES     Part 1: IF 100 Hz, Mode 6/6 Ramp, Time 20 Minutes     Part 2: NMES 70 Hz, 2 secs Ramp Up, 6 secs On, 12 secs          Off , Time 10 Minutes     Program 6 Interferential Vectoring