Datex Ohmeda - Aestiva/5
by Datex Ohmeda

Follow Us
DESCRIPTION

More than superior ventilation. 

The Aestiva 5 offers exceptional capabilities and flexibility, giving a cost-effective approach to anesthesia therapy.

The Aestiva 5 with SmartVent offers users selected capabilities of an intensive care ventilator, saving users the cost of bringing a separate ICU ventilator into the OR. Its flexible ergonomic design and intuitive operations enhance SmartVent's capabilities to give users a higher level confidence and control. In addition, the Aestiva/5 provides an optimized system for the practice of low and minimal flow anesthesia, minimizing agent consumption to save on anesthetic agent costs.

The Aestiva 5 open architecture gives users the flexibility to use their current monitors and data management systems, helping users stay within their budget while achieving physical integration in one unit. The Aestiva/5 also has built-in service diagnostics making service support easy and cost efficient.

FORUMSView All (3)
Ask a New Question

1

Reply
-Aum
7 years ago
Calibration of Flow Sensor
Difference between Inspiratory and expiratory Volume is 100ml , How do i calibrate flow sensor , Unit is Aestiva 5 with 7900 Ventilator Reply

6

Replies
-Aum
7 years ago
Calibration of Flow Sensor
Difference between Inspiratory and expiratory Volume is 100ml , How do i calibrate flow sensor , Unit is Aestiva 5 with 7900 Ventilator Reply

2

Replies
-knkmout49@aol.com
9 years ago
outlets

What are the recommendations for using outlets on the anesthesia machine?

Reply
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Anesthesia Gas Machine Companies

FEATURES

Superior ventilation

  • Volume mode, pressure mode, electronic PEEP 
  • Tidal volume compensation
  • One motion from mechanical to manual mode 
  • Two key presses to total standby: end case 
  • Cardiac bypass case mode

Open systems architecture

  • Lower overall height
  • User configurable drawers/shelving

Innovative patient breathing system

  • Eight machine hoses/cables integrated
  • “No tools” disassembly of components 
  • Autoclavable and latex-free
  • Responsive location of common gas outlet

Improved low flow/reduced life cycle costs

  • Fresh gas flow compensation—automatically
  • Smooth, faster acting fresh gas flow control
  • Minimum O2 flow of 50 mL
  • Dual air flow tube for low flow

SPECIFICATIONS

Height52.9 in
Length 28.7 in
Vaporizers (Max)Three
ScavengerClosed interface
Weight238 lbs
Vaporizer TypeVariable-bypass
Vent ModesVCV, PCV, SIMV (optional), pressure support ventilation (PSV), Manual/Spontaneous.
Width28.3 in