Pronk Technologies - OX-1 OxSim
by Pronk Technologies

Follow Us
DESCRIPTION
Miniaturized Optical SpO2 Pulse Oximeter Tester

The OxSim® Optical SpO2 Pulse Oximeter Tester allows biomedical engineers and clinical technicians to test and validate complete SpO2 monitoring systems, including the sensor, quickly and accurately. Compact enough to fit in a shirt pocket, the device is portable and easy to operate with just two buttons. (Generated by AI)

FORUMSView All (1)
Ask a New Question

0

Replies
-Lindsay Orr
Fri Dec 21 2018
BMET Pack PRO for On-the-Go Biomeds
Pronk Technologies introduces BMET Pack PRO: a compact and versatile package that makes it easier than ever to travel with your test equipment between hospitals and clinics. Reply
DOCUMENTS / MANUALSView All

VIDEOS

BMET Pack PRO for On-the-Go Biomeds

FEATURES


  • Simulates 4 saturation values, 3 heart rates, and 2 perfusion levels.

  • Optical technology ensures precise and reliable testing of SpO2 monitors.

  • Ideal for routine checks, equipment calibration, and medical device verification.

  • Lightweight, compact, and designed for field or lab use, making it convenient for mobile biomedical equipment testing.

(Generated by AI)

SPECIFICATIONS

Weight5 oz
Analyzer/Simulator TypePulse Oximeter

Additional Specifications

OxSim® Optical SpO2 Pulse Oximeter Tester Features:

  • SpO2 Simulations:
    • Mode 1:
      • Saturation: 85%
      • Heart Rate: 80 bpm
      • Perfusion Index: approx. 2.0
    • Mode 2:
      • Saturation: 95%
      • Heart Rate: 40 bpm
      • Perfusion Index: approx. 2.0
    • Mode 3:
      • Saturation: 98%
      • Heart Rate: 80 bpm
      • Perfusion Index: approx. 2.0
    • Mode 4:
      • Saturation: 98%
      • Heart Rate: 140 bpm
      • Perfusion Index: approx. 2.0
    • Mode 5:
      • Saturation: 99%
      • Heart Rate: 80 bpm
      • Perfusion Index: approx. 0.2
  • Size:
    • 2-1/2″ x 2-1/2″ x 1-1/4″ (6.4 x 6.4 x 3.2 cm), excluding finger section
  • Weight:
    • Only 5 oz. (0.14 kg, excluding battery)
  • Simple operation:
    • Just two buttons
  • Convenient:
    • No adapter cables to purchase or carry
  • Economical:
    • ‘Finger’ is fixed and permanent. No parts to carry or replace annually
  • Rugged:
    • Polycarbonate housing. Drop tested 65 time from a height of 3 feet (1m) to a hard surface with no failures!
  • Power:
    • 6VDC Adapter or AA battery. Compatible with the Battery Boost — run OxSim & SimCube NIBP Simulator simultaneously.
  • Battery Life:
    • Minimum 8 hours. 60 days in sleep mode (unit sleeps after 10 min. with no probe connection)
  • Warranty:
    • Four-Year Limited Warranty

Package Contents:

  • (1) OxSim® Optical SpO2 Pulse Oximeter Tester
  • (1) Power Supply (6VDC)
  • (1) AA battery
  • (1) Certificate of Calibration
  • (1) Carrying Case