GE HealthCare - Vivid i
DESCRIPTION
GE Healthcare’s new Vivid i is the miniaturized cardiovascular ultrasound system to provide high-performance, full-featured imaging in a lightweight design.
Vivid i addresses one of the biggest challenges in cardiovascular care – access to complete, real-time diagnostic information. The new system expands the reach of echocardiography by offering all the functionality and high performance of full-featured premium scale systems – but in a completely portable and wireless design that weighs 30 times less.
GE developed Vivid i by miniaturizing the components of a premium echocardiography system weighing more than 180 kilograms to provide a portable system weighing less than five kilograms. Vivid i features wireless functionality, enabling physicians to transfer files instantly from the system to other physicians for consultation, or to the patient’s bedside so that they can be more informed and involved in their healthcare decisions.
FORUMSView All (27)
2Replies2 months ago | LINES ARTIFACTS WHILE SCANNING WITH EVERY PROBE Hi everyone, I have a problem with my Ge Vivid I which I bought recently used. It worked perfectly for a month, then started showing vertical lines and artifacts in any mode with both probes. The next day everything went back to normal for another 4-5 days. When the system works well the sistem does not report any errors, while when the lines appear it reports errors in both RFI and DC offset. do you have any idea what the problem could be? Thank you Equipment: GE VIVID I Reply |
3Replies2 years ago | Vivid q Hi everybody, I have a problem with Vivid Q. System turns on but it does not recognize probes. Any help is appreciated.Reply |
3Replies3 years ago | NEED ADMIN PASSWORD TO CHANGE DATE AND TIME OF THE ECHO MACHINE I am a Biomed Technician from Papua New Guinea working in the government hospital, I do not have any service or technical manuals with me and so I really need an admin password to change the date and time of the echo machine. Please can anyone willingly help me out. My Echo machine details are as follows; Make - GE, Model - Vivid i Thanks in advanceReply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Ultrasound Systems Companies
FEATURES
- Full diagnostic and monitoring capabilities
- Advanced measurement and analysis tools
- New information management tools
Height | 2.5 in |
Length | 12 in |
Weight | 10 lbs |
Clinical Applications | Anesthesia |
Imaging Capabilities | 2D |
Portable | 1 |
Color-flow Mapping | 1 |
Doppler Modes | B-Mode M-Mode Color Doppler Power Doppler PW Doppler CW Doppler Color M-Mode |
Image Display | 15 in LCD monitor |
Imaging Mode | B/M |
Width | 14 in |
Additional Specifications
Probes that work with this system:
Linear probe 12L - RS [5 - 13 MHz]
Microconvex pediatric/ veterinary probe 8C - RS [4 - 10 MHz]
Convex probe 4C - RS [2 - 5.5 MHz]
Cardiac sector probe 3S - RS [1.5 - 4MHz]
Cardiac sector probe 5S - RS [2 - 5 MHz]
Cardiac sector probe 7S - RS [3.1 - 8 MHz]
Cardiac sector probe 10S - RS [4 - 10 MHz]
TEE Multiplane transesophageal probe 6T - RS [2.2 - 8 MHz]
TEE Multiplane transesophageal probe 9T - RS [4 - 10 MHz]
Non - Imaging Pencil Probe P2D [2 MHz]