Datascope - Passport EL
by Datascope

Follow Us
DESCRIPTION

The Datascope Passport monitor measures ECG, Respiration, NIBP, SPO2, and Temperature. The Passport has a large electroluminescent screen for easy viewing from any angle. This monitor is operated with easy to use, single function keys.

FORUMSView All (8)
Ask a New Question

1

Reply
-Joe Robbins
3 years ago
Looking for a service manual
Im looking for the service manual for a datascope passport el. For some reason the link on here i cant get it to download. Just looking for some assistance. Reply

4

Replies
-JMaple
7 years ago
User manual
I'm trying to locate the user manual for the Datascope - Passport ELReply

2

Replies
-leemash
8 years ago
Looking for Service and user manual

Hello I am looking for a service and a user manual for the EL any help would be great.

 

Thanks

 

Lee

Reply
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Vital Signs/Multi-Parameter Companies

FEATURES

[list]      ECG      [*] Leads: I, II, III      [*] Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ± 10%      [*] Frequency response to screen: ESU filter out: 0.5 to 40 Hz, -3db max @ 1 mVpp input; ESU filter in: 0.5 to 20 Hz -3db max @ 1 mVpp input             Heart Rate Meter      [*] Range: 30-300 bpm adult/child. 30-350 bpm neonatal      [*] Accuracy: 30-250 bpm ± 3bpm or 3%, whichever is greater.      [*] Pacer rejection: rejects all pulse of amplitude ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with no tail. Rejects all pulses ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with 100 ms T.C. tail <0.8 mV or 25 ms T.C. tail <0.4 mV.      [*] Display update: 2 seconds ± 0.1 sec             NIBP      [*] Technique: oscillometric      [*] Systolic range: adult/ped mode: 40-250 mmHg, neonate mode: 15-150 mmHg.      [*] Diastolic range: adult/ped mode: 30-200 mmHg, neonate mode: 10-150 mmHg.      [*] Systolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 3 mmHg, standard deviation less than 13 mmHg (neonatal).      [*] Diastolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 4 mmHg, standard deviation less than 7 mmHg (neonatal).      [*] Heart rate meter range: 30-250 bpm.      [*] Heart rate meter accuracy: ±3 bpm or ±3%, whichever is greater.             Pulse Oximetry      [*] Accuracy (1standard deviation): 70-100%, ±2% 60-69%, ±4% 0-59%, unspecified.      [*] Response time: 13 seconds to 95% of final step change % SpO2 value from 60-95% at 72 bpm       [/list]

SPECIFICATIONS

Height9.5 in
Length 8 in
Weight13 lbs
Width13 in

Additional Specifications

Power Consumption: 15 watts typical      Voltage input: 100, 120, 220, 240 VAC ± 10%      Mains frequency: 47 to 65 Hz