Datascope - Passport EL
DESCRIPTION
The Datascope Passport monitor measures ECG, Respiration, NIBP, SPO2, and Temperature. The Passport has a large electroluminescent screen for easy viewing from any angle. This monitor is operated with easy to use, single function keys.
FORUMSView All (8)
1Reply3 years ago | Looking for a service manual Im looking for the service manual for a datascope passport el. For some reason the link on here i cant get it to download. Just looking for some assistance. Reply |
4Replies7 years ago | User manual I'm trying to locate the user manual for the Datascope - Passport ELReply |
2Replies8 years ago | Looking for Service and user manual Hello I am looking for a service and a user manual for the EL any help would be great.
Thanks
Lee Reply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Vital Signs/Multi-Parameter Companies
FEATURES
[list] ECG [*] Leads: I, II, III [*] Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ± 10% [*] Frequency response to screen: ESU filter out: 0.5 to 40 Hz, -3db max @ 1 mVpp input; ESU filter in: 0.5 to 20 Hz -3db max @ 1 mVpp input Heart Rate Meter [*] Range: 30-300 bpm adult/child. 30-350 bpm neonatal [*] Accuracy: 30-250 bpm ± 3bpm or 3%, whichever is greater. [*] Pacer rejection: rejects all pulse of amplitude ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with no tail. Rejects all pulses ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with 100 ms T.C. tail <0.8 mV or 25 ms T.C. tail <0.4 mV. [*] Display update: 2 seconds ± 0.1 sec NIBP [*] Technique: oscillometric [*] Systolic range: adult/ped mode: 40-250 mmHg, neonate mode: 15-150 mmHg. [*] Diastolic range: adult/ped mode: 30-200 mmHg, neonate mode: 10-150 mmHg. [*] Systolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 3 mmHg, standard deviation less than 13 mmHg (neonatal). [*] Diastolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 4 mmHg, standard deviation less than 7 mmHg (neonatal). [*] Heart rate meter range: 30-250 bpm. [*] Heart rate meter accuracy: ±3 bpm or ±3%, whichever is greater. Pulse Oximetry [*] Accuracy (1standard deviation): 70-100%, ±2% 60-69%, ±4% 0-59%, unspecified. [*] Response time: 13 seconds to 95% of final step change % SpO2 value from 60-95% at 72 bpm [/list]
Height | 9.5 in |
Length | 8 in |
Weight | 13 lbs |
Width | 13 in |
Additional Specifications
Power Consumption: 15 watts typical Voltage input: 100, 120, 220, 240 VAC ± 10% Mains frequency: 47 to 65 Hz