Colin Medical - YM6000
by Colin Medical

Follow Us
DESCRIPTION
The YM6000 is a sophisticated monitor using the best technologies.

The dynamic linear deflation NIBP module guarantees greater patient comfort, shorter measurement time and improved accuracy for all adult, pediatric and neonate patients. The new SpO2 module with sensors lets you take full advantages of the ongoing advances in pulse oximetry. Up to 24hrs tabular and graphical trends show all parameters to support    clinician's decisions whenever necessary. The central monitoring system displays real time and dual waveforms (Standard model) or 4 analysis waveforms to enable a single clinician to care for 16 to 32 patients effectively.

FORUMSView All (2)
Ask a New Question

1

Reply
-North Scottsdale ASC
3 years ago
Monitor Housing Assembly
Can I buy replacement partReply

1

Reply
-Valley Surgery
6 years ago
Standby
How do you put the monitor on standby? Reply
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Vital Signs/Multi-Parameter Companies

FEATURES

[list]    [*] Available parameters include 3 or 5 lead ECG, Respiration, NIBP, Sp02, 2 temperatures, included battery and optional 2IBP, EtC02, and built-in printer    [*] High quality 12.1 inch color TFT LCD screen enables you to monitor 6 traces with 10 numerics vital sign clearly even under the most difficult lighting conditions.    [*] 6 color coded keys and a trim knob admits clinicians to quickly access monitoring function controls.     [*] The optimized 2 packs of Ni-MH rechargeable batteries, a wheeled mobile cart and an integrated top handle ensure continuous monitoring under any transport circumstances.     [*] Connectivity to the central monitoring system enables users to receive alarm signal automatically when the patient's condition turns critical. Also the stored event or real time vital sign can be re-called to review and print with any PC printer through the network.    [/list]

SPECIFICATIONS

Height305 mm
Length 172 mm
Weight5.5 kg
Width341 mm

Additional Specifications

Power Requirements: AC Mains 100Vac-240V~50Hz/60Hz, 63-110VA    Temperature Range: 15C to 45C    ECG Measurement Range: 30 BPM to 350 BPM    Respiration Rate Range: 0.3 to 120 breaths/min    NIBP Pulse Rate Range: Adult/Pediatric 30 BPM to 260 BPM    Sp02 Pulse Rate Range: 0 and 20 BPM to 250 BPM    Capnography Range: 0 - 150mmHg     IBP Pulse Rate Range: 20 BPM - 250 BPM

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree