Bovie - IDS-300
DESCRIPTION
Intelligent Digital System[b]IDS technology gives the surgeon the flexibility to consistently choose the type of effect desired with maximum convenience and safety.[/b] The Bovie® IDS Series are innovative electrosurgical generators with fully digital implementation for use in today’s modern OR and surgical outpatient center. The Bovie-IDS units are easy-to-handle yet capable of covering a whole spectrum of electrosurgical interventions. Monopolar and bipolar functions satisfy all surgical demands with maximum safety and a user-friendly interface. Bovie’s digital technology makes controlling the IDS Systems very simple for the OR team, allowing the surgeon to concentrate on what’s important – the operation and the patient.
FORUMSView All (4)
0Repliesa year ago | Bovie ids 300 Hello I am Khalid from Pakistan. I have bovie ids 300 and giving error E2 and E3 .someone can help me. Someone can provide me service manual. ThanksReply |
0Repliesa year ago | Bovie ids 300 Hello I am Khalid from Pakistan. I have bovie ids 300 and giving error E2 and E3 .please provide me technical support /service manual. ThanksReply |
3Replies4 years ago | equipment failure bovie ids 300 equipment failure bovie ids 300 does not increase fixed power in coagulation mode, even if the values are changed on displayReply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Electrosurgical Unit (ESU) Companies
FEATURES
Safety is digitally designed inside. IDS technology meets the requirements of a variety of medical specialties, procedures, and indications in the modern OR. BovieFDFS™ (Fast Digital Feedback System) The digitally controlled CUT and COAG functions give a consistent clinical output. For the first time in electrosurgery, through digital technology, we are able to measure tissue impedance in real time (5000 times a second). As the impedance varies, the power is adjusted to deliver a consistent clinical effect. BovieNEM™ (Neutral Electrode Monitoring) Improved patient safety with the latest digital implementation. BovieFCFS™ (First Come First Served) Discrete output design allows only one output device to be activated at any given time. BovieDED™ (Digital Error Detection) Safety for the surgeon, OR staff, and patient. At the sign of any problem, the unit instantly disables the output, sounds an alarm and displays the appropriate error code.
Height | 6 in |
Length | 16.25 in |
Weight | 19 lbs |
OutPut Frequency | 490 kHz ±5 |
Output Power | 300 W |
Width | 12.25 in |
Additional Specifications
Output Power Cut: 300W @ 300Ω Cut II: 300W @ 300Ω Blend: 200W @ 300Ω Pinpoint: 120W @ 500Ω Spray: 80W @ 500Ω Bipolar: 80W @ 150Ω Duty Cycle: 10 S / 30 S Output Type: RF Isolated "F" Input Current: 4.5 A ~ Line Voltage: 100-240 V ~