The right temperature, in the right place, at the right time.

When it comes to fluid warming, there is a system that can help you maintain normothermia with accuracy, mobility and speed. The enFlow* system from GE Healthcare delivers the right temperature in the right place at the right time. enFlow can help providers deliver higher quality care to more people—part of GE’s healthymagination commitment.                            enFlow can help maintain normothermia across your patient population with accuracy, mobility and speed.                            [b]The Right Temperature[/b]              By consistently helping to maintain the right patient temperature, enFlow brings the opportunity for both clinical and economic benefits to your hospital. Maintaining normothermia can help lessen complications and speed up recovery time – all while reducing length of stay and hospital costs.                            [b]The Right Place[/b]              True system mobility and a small transferable cartridge allow enFlow to help maintain normothermia in the right place-- throughout all care areas. It can be used before, during and after procedures, and because its cartridge is easily transported from room to room, enFlow maintains your workflow while saving steps.                            [b]The Right Time[/b]              The enFlow system enables warmed infusate delivery at the right time across all clinical areas—right away, and within seconds. Its low priming volume reduces the time needed to reach temperature set point thus allowing the warming process to start quickly, while its close proximity to the patient reduces heat loss across the IV line.

FORUMSView All (1)
Ask a New Question

1

Reply
-CalDave
6 years ago
Manual
Does anyone have the service manual for these that you can send me? DaveReply

FEATURES

[list]    Accuracy    [*] The system warms fluids automatically to 40 ± 2°C and has redundant sensors to ensure fluid temperature accuracy.              [*] The lightweight warmer (9.5 oz) can be placed close to the patient -- allowing less opportunity for fluid-cooling in the IV line.              [*] It has a low priming volume (4mL), which reduces waste and improves control over fluid composition.              [*] The warmer incorporates a layer that transfers heat effectively and prevents hot spots             Mobility  [*] When it’s time to move, the cartridge and the IV set are removed from the warming unit only to be reinserted into a warmer in the next area.              [*] The warming unit and power source are highly durable and have been shock and vibration tested.              [*] The cartridge may stay in-line to protect the IV set from potential infection -- whether fluid is being warmed or not.              [*] The enFlow cartridge can be used for 24 hours of continuous patient warming.     Speed  [*] It warms fluids rapidly (18 s or less) to a temperature of 40 °C, so there’s no time spent waiting to warm (other warmers can take over 10 min).              [*] The cartridge attaches in-line to standard IV sets at the start of procedures, so there’s no additional set-up or tubing requirements.              [*] It offers one-button operation. It's intuitive and relatively easy to operate, simply turn on the power and be warming within seconds.              [*] It requires little preventive maintenance (five year schedule) and no calibrations.    [/list]

SPECIFICATIONS

Height1.2 in
Length 5 in
Weight9.7 oz
Width2.5 yd

Additional Specifications

Fluid Temperature Output: 40 °C ± 2 °C              Flow Rate Range: KVO to 200 mL/min