Thermo Scientific - Arena 30
by Thermo Scientific

Follow Us
DESCRIPTION
Allows the use of multiple chemistries with excellent automated pre and post dilution features

The Thermo Scientific Arena 30 analyzer is a fully open, random access automated photometric system well suited for product analysis and quality control in food and beverage, and in other industrial processes. Applications cover methods for wine, juice, beer, milk, honey, potatoes and special food measurements. The Thermo Scientific Arena 30 offers reliable and cost-effective automated sample analysis in a user friendly way. Continuous access to samples, reagents and cuvettes without interrupting the testing process facilitates laboratory workflow.

FORUMSView All
Ask a New Question

FEATURES

[list]       [*] Open system for various colorimetric and enzymatic applications       [*] Capacity of up to 300 tests/hour       [*] On-board capacity of 84 samples, calibrators and controls, 6 segments with 14 positions per segment       [*] Possibility to have interface into the automated sample track system       [*] 39 fixed, cooled calibrator and control positions       [*] 45 reagent positions, automatic identification by integrated bar code reader       [*] 600 reaction cell positions on-board       [*] Can easily set up own applications using several user definable parameters, one of which is a measurement temperature       [*] Selectable measurement temperature from 30 to 50°C, preset to 30, 37 and 50°C       [*] Measurement wavelengths range from 340 to 880nm       [/list]

SPECIFICATIONS

Height120 cm
Length 82 cm
Power Requirements100-240 VAC
Weight300 kg
Width140 cm + arm max 80cm

Additional Specifications

[list]  Operating Principle:       Fully open, random access photometric analyzer. Programmable tests up to 200.       Samples:       Samples are placed on sample disk in segments with 14 positions each. Max 6 segments on board. Possibility to have interface into automated sample track. 39 fixed calibrator and control positions.       Reagents:       Continuous-loading 45 positions in the refrigerated reagent compartment.       Cuvets:       Discrete disposable multicell cuvet with 12 reaction measurement cells in a row. Continuous loading. On board capacity 600 reaction positions.       Dilutions:       Automatic sample pre-dilution. Automatic sample dilution of overrange tests with automatic re-run.       Quality Control:       Real-time QC with multiple and variable rules. Programmable control interval. Daily and cumulative reports.       Water Consumption:       Distilled water consumption typically <1.5L/hr. Available on board.  [/list]

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree