Fluke Biomedical - ProSim SPOT Light
by Fluke Biomedical




Featuring an exclusive ergonomic design, the ProSim SPOT Light is the first comprehensive SpO2 functional tester to come in a handheld and easy-to-use device. SPOT Light is lightweight and flexible with three custom presets specially-designed to make it the fastest and easiest-to-use pulse oximeter analysis device on the market today for SpO2 functional testing. A helpful LCD display and three simple buttons make it effortless to rapidly change parameters and view each signal output sent to the pulse oximeter at a glance. An interchangeable, long-life battery ensures uninterrupted all-day operation without need to connect to a power supply. SPOT Light sets up in seconds to send Peripheral capillary oxygen saturation (SpO2), heart rate, perfusion, transmission, artifact noise, and eight different manufactures custom r-curves to a pulse oximeter or patient monitor. It is designed to take the abuse of everyday use, including the stresses of transportation, moving from room to room and device to device, and the occasional fall from the workbench. An increasing number of medical devices now have pulse oximetry built in. SPOT Light can be paired with other Fluke Biomedical test tools to make modern device testing task fast and easy. Need to check a defibrillator with pulse oximetry? SPOT Light with the Impulse 7000 Defibrillator Analyzer allow you to test any external defibrillator on the market today. Do you have a fleet of new patient monitors coming that require incoming inspection? Using SPOT Light with ProSim 4 Vital Signs Simulator allows you to easily accomplish this task out in hours instead of days.
0RepliesSun Jun 24 2018 | ProSim SPOT Light SpO2 Functional Tester Video Demonstration ProSim SPOT Light SpO2 Functional Tester Video DemonstrationReply |
0RepliesSun Jun 24 2018 | Troubleshooting SpO2 Patient Monitors with ProSim SPOT Light SpO2 Functional Tester Troubleshooting SpO2 Patient Monitors with ProSim SPOT Light SpO2 Functional TesterReply |
0RepliesSat Dec 24 2016 | need firmware hallo a have a (old) spotlight and want to upgrade the firmware. There currently 1.01 is installed. can send me anyone a newer one? many thanks and happy christmas Reply |
[list] [*] Small, portable and lightweight [*] Large, easy to read LCD display [*] Rechargeable battery lasts 10 hours minimum [*] Signal strength indicator [*] SpO2 Saturation: 80 %, 85 %, 90 %, 95 %, 97 %, 98 %, 99 % and 100 % [*] Heart rate: 30, 60, 80, 100, 120, 150 and 245 BPM [*] Perfusion: 0.2 %, 2 % and 10 % [*] Transmission: dark/thick, normal and light/thin [*] Artifacts: respiration and ambient light [*] R-curves: Nonin, Masimo, Nellcor, Nihon Kohden, Mindray, GE, Philips, BCI [/list]
| Height | 1.9 in |
| Length | 3.8 in |
| Power Requirements | 100-240 VAC |
| Weight | 8.8 oz |
| Analyzer/Simulator Type | Pulse Oximeter |
| Width | 4.8 in |
Fluke Biomedical announced today the new ProSim SPOT Light SpO2 Functional Tester is the first biomedical test tool on the market to achieve the RoHS E Environmentally-Friendly label.

The spot light SpO2 functional tester is the newest addition to Fluke Biomedical’s ProSim family of patient monitor quality-assurance testing and troubleshooting tools.