KOPP Development Inc. - FerrAlert™ SOLO
by KOPP Development Inc.

Follow Us
DESCRIPTION
The best FMD solution for ACR Zone - 3 Screening

Installed in the controlled pre-screening zone, FerrAlert™ SOLO is the highest sensitivity, full-body patient and personnel screener available to MRI providers.

FORUMSView All (1)
Ask a New Question

1

Reply
-gnaso
9 years ago
screening labs

I am a patient who need to have a magnetic resonance and I would like to be screened for possible adverse consequences due to implanted clips of unknown nature. Could you please tell me if there are magnetic resonance laboratories in Italy that have FerrAlert detection systems ? Thanks. Giovanni naso. naso.giovanni@libero.it - http://www.digilander.it/gnaso

Reply

FEATURES

[list]      [*] Instantly PINPOINTS location of the ferromagnetic object, allowing Technologist to quickly identify and remove the ferromagnetic threat – NO invasive PAT-DOWN required      [*] Limits alarm fatigue – Patented technology suppresses irrelevant warnings and false positive alarms caused by hallway traffic      [*] 12 location-accurate sensors for uniform sensitivity, reliability and usability      [*] An intelligent pre-alarm indicator - Constantly monitors the ambient magnetic field and provides early visual warning of approaching ferrous objects      [*] No-Touch Activation safeguards against cross-contamination      [*] Consistent, unambiguous and simple Self-Screening or Supervised Screening      [*] Elegant, Small Footprint Installation      [*] Available as a portable, battery-powered system to suit any facility’s needs      [*] Integrates easily into any established screening procedures      [*] Inexpensive – affordable for any MRI facility      [*] Conforms to ES60601-1-8 international standards for medical device alarms      (Does not cause alarm fatigue. No RED alarm lights, as color RED must be used ONLY in life threatening situations)      [*] Conforms to IEC 60101-1:2005 medical device specification requirements       (Ferromagnetic detectors are not considered to be medical devices; however, they are an integral part of the medical environment. As such, it is highly important that the power supply used in the detectors complies with standards for medical equipment used by the FDA, UL, as well as agencies around the world.)      [/list]

Additional Specifications

Number of Detection Zones: Six (6)      Height of Uniform Sensitivity: Greater than six (6) feet      Hazard Location Indicators: Four (4) amber flashing lights at height of threat and on a display at the top of array      Ambient Magnetic Disturbance Indicator: Eight (8) blue bars      Ferromagnetica Hazard Sensitivity: Adjustable      Audio Indicator: Selectable, adjustable volume      Mounting: Wall or free-standing with optional base      Power Requirement: 100 to 240 VAC 47 to 63 Hz 42 watts      Battery Operation: Optional      Dimensions: Height 86 ¼” (220 cm), Depth 2 ½” (6.5 cm), Width 2” (5 cm)