Fluke Biomedical - VT305
by Fluke Biomedical

Follow Us
DESCRIPTION
Simple. Portable. Efficient.

The VT305 Gas Flow Analyzer is a powerful, compact solution for testing medical gas flow and pressure devices with speed and precision. Designed specifically for biomedical engineers and healthcare technicians, the VT305 goes beyond basic flow measurement to provide comprehensive performance analysis of devices like endoscopic insufflators, anesthesia machines, oxygen flow meters, pressure gauges, and suction devices. (Generated by AI)

FORUMSView All (2)
Ask a New Question

0

Replies
-MedWrench Intern
Sun Jun 24 2018
Medical Gas Flow Calibration with a Fluke Biomedical VT305
Justin Ross shows how to calibrate gas flow using a Fluke Biomedical VT 305.Reply

0

Replies
-MedWrench Intern
Sun Jun 24 2018
Gas Flow Testing with a Fluke Biomedical VT305 Gas Flow Analyzer
Justin Ross shows how to measure gas flow with a Fluke Biomedical VT305 Gas Flow Analyzer.Reply
DOCUMENTS / MANUALSView All

VIDEOS

Medical Gas Flow Calibration w...
Gas Flow Testing with a Fluke ...

FEATURES

  • Measures flow, pressure, oxygen concentration, and gas temperature for full diagnostic capability

  • Compatible with a wide range of medical gas and pressure-generating devices

  • Internal sensors ensure fast and secure connections to devices under test

  • Four-button front panel for easy navigation and real-time view switching

  • Onboard waveform graphing for instant visual analysis

  • 2 GB SD card for convenient data storage and retrieval

  • Includes Windows-compatible utility software for reviewing, printing, and documenting test results

  • Compatible with Ansur test automation software, supporting workflow efficiency and regulatory compliance

  • Streamlined templates and drag-and-drop editing help standardize testing procedures, minimize user error, and meet OEM service requirement


(Generated by AI)


SPECIFICATIONS

Height7 cm
Length 11.4 cm
Power Requirements100-240 VAC
Weight0.4 kg
Analyzer/Simulator TypeGas Flow
Width6 cm

Additional Specifications

Display: 26 x 33 mm, reflective CLCD        Operating Flow Range: ± 300 slpm        Accuracy: ± 1.9 % or ± 0.1 l/min, whichever is greater        Gas Temperature: Range - 0 to 50 °C; Accuracy - ± 1.75 % or ± 50 °C

NEWSView All
Fluke Announces Advantage Training News for April

Fluke Announces Advantage Training News for April

Fluke Announces Advantage Training News for April

Fluke Biomedical Advantage Training News

No-cost training on medical device performance and safety testing, documenting for regulatory compliance, productivity improvement, and using test instruments effectively.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.
I Agree