Mindray - A3
DESCRIPTION
Clear | Explicit | PreciseIntroducing the A3 Anesthesia System. The delivery system that merges intuitive simplicity with advanced technology. Today’s anesthesia professional demands intuitive ways to deliver the technology that can provide better patient care. With a focus on key ventilation modes, a large easy to see display, touch screen control, and by eliminating menus, trim knobs and dedicated buttons, the A3 promotes simple utilization of its key ventilation features. Experience the convergence of value and performance.
FORUMSView All (3)
0Replies3 years ago | A3 pipeline Air gauge Hi, Anyone have to replace a pipeline air gauge on the Mindray A3? It looks very involved. If you know any easy way to access the gauge, please let me know. Thanks.Reply |
2Replies7 years ago | FDA Recall Found a recall for a gasket leak. It did date back to 2012 but, I can not seem to find a manufacture date and we have only had them for a little over a year. Is/ could this still be an issue.Reply |
0Replies10 years ago | check out procedure Looking for a checklist to perform the annual verification testing Reply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Anesthesia Gas Machine Companies
FEATURES
[list] [*] Volume Control Ventilation (VCV) [*] Pressure Control Ventilation (PCV) [*] Pressure Support (PS) ventilation [*] Synchronized Intermittent [*] Mandatory Ventilation with volume control (SIMV-VC) [*] Manual/spontaneous breathing mode with respiratory monitoring capability [*] 15" touch-screen user interface [*] Breathing System maintained near 35¬ C and virtually eliminates internal condensation [*] Auxiliary Oxygen/Air flow meters deliver blended gas [*] Automatic compliance and fresh gas compensation maintain accurate tidal volumes with a wide range of fresh gas flows and breathing circuits [*] Economical single container absorber reduces compressible volume and accepts non-proprietary prepackaged and loose fill absorbent [*] Deck lighting with adjustable brightness [*] Individual wheel brakes on all four casters [*] Available with optional DPM patient monitor (shown) [/list]
Gases | Air, Nitrous Oxide, Oxygen |
Vaporizers (Max) | Two |
Inspiratory Flow (max) | 50 L/min |
FDA AlertsView All
Class 1 Recall: Mindray A3 and A5 Anesthesia Delivery System
The affected anesthesia delivery systems may have a gasket leak which could cause an interruption of or inadequate patient anesthesia and ventilation, temporary or permanent patient injury, or death.