Hillrom - TotalCare SpO2RT 2
DESCRIPTION
ICU BedComplications related to immobility and long term ventilation - such as pulmonary secretions which can lead to nosocomial pneumonia and neuro-muscular dysfunction - are among the most commonly acquired adverse events in critical care. Complexity and cost of care in affected patients increases significantly. The TotalCare SpO2RT® 2 Therapy Bed helps caregivers treat patient complications by supporting early mobility strategies in ICU patients. Technology specifically designed to drive evidence based protocol compliance guides caregivers and patients through scientifically acknowledged steps of verticalization and early mobility. The fully integrated TotalCare SpO2RT® 2 surface synchronizes with the frame when any function is activated.
FORUMSView All (29)
1Replya month ago | Foot hit floor Foot hit floor when unmade chair, Any suggestion? Reply |
0Replies4 months ago | Bed suddenly lost powet I have a TotalCare SpO2RT that suddenly lot power. The power cable was then unplugged and reconnected. I checked that the power cable was connected to the PCB board and it was. I plugged the bed back in and I heard the clicking sounds but the bed did not receive power and the blower did not start. The bed is in a high position and I cannot get it to lower. Reply |
0Replies8 months ago | Manual I want to download the manual Equipment: Hillrom - TotalCare SpO2RT 2 Reply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Bed Companies
FEATURES
[list] [*] Continuous Lateral Rotation Therapy [*] Percussion and Vibration Therapy [*] Weight based pressure redistribution in any bed position [*] Advanced Microclimate Management technology [*] Point-Of-Care® siderail controls with Graphical Caregiver Interface feature (GCI) [*] Digital Head of bed angle indicator and alarm [*] 3 mode bed exit sensor with alarm silence and alarm suspend modes [*] FullChair® and chair egress with stand assist [*] One-button Boost® patient repositioning support [*] Turn assist [*] Optional IntelliDrive® powered transport [*] FlexAfoot® electrical bed retraction and extension [*] HandsFree™ emergency CPR and Trendelenburg [*] History data on patient weight, head of bed elevation, chair position, and pulmonary therapies [*] Therapy reminders [*] Safety stop and alarm for pulmonary therapies when side rails are down [/list]
Height | 17.5 in to 36.5 inhces |
Bed Type | Electric |
Length | 81.5 in 93 inches fully extended |
Patient Weight Capacity | 550 lbs |
Width | 38 in to 40 inches |
Additional Specifications
Trendelenburg/Reverse Trendelenburg: 15°/15° Max Head elevation: 75°