GE HealthCare - Marquette Case 8000
by GE HealthCare

Follow Us
DESCRIPTION
The GE Marquette Case 8000 stress test system

The GE CASE 8000 Stress Test System is a high-performance cardiac stress testing platform engineered for clinical accuracy and biomedical reliability. Designed with 14-channel acquisition and fully programmable lead configurations, this system supports advanced diagnostic workflows in hospitals, cardiology labs, and biomedical engineering departments. Operating on robust NT technology, the CASE 8000 stores patient data and test results securely on an internal hard drive for efficient retrieval and long-term record management. Its integrated Thermal Dot Array printer delivers precise, high-resolution ECG reports directly at the point of care. Known for its sophisticated design and dependable performance, the GE CASE 8000 provides biomedical engineers with a trusted, serviceable solution for optimizing cardiac stress testing and maintaining consistent clinical performance. (Generated by AI)

Powered by Froala Editor

FORUMSView All (2)
Ask a New Question

2

Replies
-sabry
Wed May 08 2019
Password needed
Machine ask for password. Anybody can help? Reply

2

Replies
-kgrif222
Thu Feb 09 2017
Troubleshooting CASE 8000 error 7963
When setting up for a stress test, we suddenly began getting an error message 7963 on our Case 8000 saying there is no communication with the treadmill. It was working fine on Friday but this began on Monday. All of the connections and cables were double checked. The outlet to the treadmill was checked for power. The emergency button is released. We have tried rebooting the system several times. Any suggestions?Reply
SERVICE COMPANIESView All Electrocardiograph (EKG / ECG) Companies

FEATURES

[list]    [*] 15 lead capability    [*] 12SL interpretive ECG analysis    [*] Full page records    [*] Arrhythmia detection    [*] Windows platform    [*] Dedicated hard keys for an easy user interface    [*] 3.2 GB internal memory    [*] Color CRT display    [*] Alphanumeric keyboard operation    [*] Integrated thermal array recorder    [*] AC power    [*] ECG cable and lead set    [*] GE T2000 Treadmill (220 VAC power required)    [/list]

SPECIFICATIONS

EKG/ECG TypeStress
Height63 in with monitor
Length 34 in
Weight190 lbs
Image Display15 in
Width104 in with paper tray

Additional Specifications

Display:    [list]    [*] Display type: High-resolution, color 0.25 mm dot pitch raster-written CRT    [*] Display resolution: 1024 x 768 x 70 Hz refresh    [*] Display size: 15* (standard) diagonal SVGA    [*] Monitored leads: 3, 6 or 12    [*] Displayed leads: Number on screen 3 or 6 (12 lead check)    [*] Display format: 3 rhythm, 3 rhythm + medians, 3 rhythm + trends, 6 rhythm, 4 x 2.5 + 1 rhythm, 2x6    [*] Display speeds: 25, 50 mm/s    [*] Display sensitivity/gain: 2.5, 5, 10, 20 mm/mV    [*] Displayed vital signs data (configurable): Heart rate, target heart rate, blood pressure, exercise clock, stage clock, phase clock, protocol, speed, grade, Watts, METS, RPP, and SpO2    [*] Displayed data: ST scan/median complexes, arrhythmia's, ventricular ectopic/min counter, 3 to 15 waveforms, lead check torso and 12 leads, waterfall display, trends, tabular summary, stored ECG strips, interpretation, time-of-day clock, patient name, warning messages and prompts    [/list]        Writer:    [list]    [*] Writer technology: "Instant" load, thermal dot array    [*] Writer leads: 3, 6, 12 or 15 leads (standard, NEHB, Cabrera, configurable)    [*] Writer speeds: 5, 12.5, 25 and 50 mm/sec (± 2%)    [*] Writer sensitivity/gain: 2.5, 5, 10 or 20 mm/mV (± 5%)    [*] Writer resolution: Horizontal 1000 lines/sec x 200 dpi dedicated local printing. 200 x 200 dpi generic printing    [*] Paper type: Thermal, perforated, fan fold, 300 sheets/pack    [*] Paper size: A size 214.63 x 280 mm (8.45 x 11 in) A4 size 210 x 297.5 mm (8.27 x 11.7 in)    [/list]

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.