The GE CASE 8000 Stress Test System is a high-performance cardiac stress testing platform engineered for clinical accuracy and biomedical reliability. Designed with 14-channel acquisition and fully programmable lead configurations, this system supports advanced diagnostic workflows in hospitals, cardiology labs, and biomedical engineering departments. Operating on robust NT technology, the CASE 8000 stores patient data and test results securely on an internal hard drive for efficient retrieval and long-term record management. Its integrated Thermal Dot Array printer delivers precise, high-resolution ECG reports directly at the point of care. Known for its sophisticated design and dependable performance, the GE CASE 8000 provides biomedical engineers with a trusted, serviceable solution for optimizing cardiac stress testing and maintaining consistent clinical performance. (Generated by AI)
Powered by Froala Editor
2RepliesWed May 08 2019 | Password needed Machine ask for password. Anybody can help? Reply |
2RepliesThu Feb 09 2017 | Troubleshooting CASE 8000 error 7963 When setting up for a stress test, we suddenly began getting an error message 7963 on our Case 8000 saying there is no communication with the treadmill. It was working fine on Friday but this began on Monday. All of the connections and cables were double checked. The outlet to the treadmill was checked for power. The emergency button is released. We have tried rebooting the system several times. Any suggestions?Reply |
[list] [*] 15 lead capability [*] 12SL interpretive ECG analysis [*] Full page records [*] Arrhythmia detection [*] Windows platform [*] Dedicated hard keys for an easy user interface [*] 3.2 GB internal memory [*] Color CRT display [*] Alphanumeric keyboard operation [*] Integrated thermal array recorder [*] AC power [*] ECG cable and lead set [*] GE T2000 Treadmill (220 VAC power required) [/list]
| EKG/ECG Type | Stress |
| Height | 63 in with monitor |
| Length | 34 in |
| Weight | 190 lbs |
| Image Display | 15 in |
| Width | 104 in with paper tray |
Display: [list] [*] Display type: High-resolution, color 0.25 mm dot pitch raster-written CRT [*] Display resolution: 1024 x 768 x 70 Hz refresh [*] Display size: 15* (standard) diagonal SVGA [*] Monitored leads: 3, 6 or 12 [*] Displayed leads: Number on screen 3 or 6 (12 lead check) [*] Display format: 3 rhythm, 3 rhythm + medians, 3 rhythm + trends, 6 rhythm, 4 x 2.5 + 1 rhythm, 2x6 [*] Display speeds: 25, 50 mm/s [*] Display sensitivity/gain: 2.5, 5, 10, 20 mm/mV [*] Displayed vital signs data (configurable): Heart rate, target heart rate, blood pressure, exercise clock, stage clock, phase clock, protocol, speed, grade, Watts, METS, RPP, and SpO2 [*] Displayed data: ST scan/median complexes, arrhythmia's, ventricular ectopic/min counter, 3 to 15 waveforms, lead check torso and 12 leads, waterfall display, trends, tabular summary, stored ECG strips, interpretation, time-of-day clock, patient name, warning messages and prompts [/list] Writer: [list] [*] Writer technology: "Instant" load, thermal dot array [*] Writer leads: 3, 6, 12 or 15 leads (standard, NEHB, Cabrera, configurable) [*] Writer speeds: 5, 12.5, 25 and 50 mm/sec (± 2%) [*] Writer sensitivity/gain: 2.5, 5, 10 or 20 mm/mV (± 5%) [*] Writer resolution: Horizontal 1000 lines/sec x 200 dpi dedicated local printing. 200 x 200 dpi generic printing [*] Paper type: Thermal, perforated, fan fold, 300 sheets/pack [*] Paper size: A size 214.63 x 280 mm (8.45 x 11 in) A4 size 210 x 297.5 mm (8.27 x 11.7 in) [/list]