Masimo - EMMA Capnometer
by Masimo

Follow Us
DESCRIPTION

Carbon Dioxide Monitor 

The Masimo EMMA Capnograph Kit (#3639) includes an EMMA Capnograph (mmHG), EMMA Pouch, EMMA Lanyard, and two AAA Batteries.


FORUMSView All
Ask a New Question
DOCUMENTS / MANUALSView All

FEATURES

  • Simple, easy-to-use interface for quick setup and one-touch programming
  • Audible and visual alarm system for No Breath Detected, No Adapter, Check Adapter, and adjustable high and low EtCO2 alarm 
  • Minimal warm-up time, with EtCO2 and respiration rate measurements and real-time EtCO2 waveform displayed in 15 seconds.
  • Lightweight design fits in the palm of your hand for mobility and convenience during short-term EtCO2 monitoring of adult, pediatric, and infant patients.
  • Designed to fit easily onto a breathing circuit.
  • Flexible use at multiple points of care including pre-hospital, emergency medicine, operating room, intensive care unit, and long-term acute care.
  • Rugged design for reliable operation in challenging environments.
  • No routine calibration required.
  • Audible and visual alarm system for No Adapter, Clogged Adapter, Apnea, Low Battery, and adjustable High and Low EtCO2 alarm.

Additional Specifications

  • EMMA requires minimal warm-up time — just 15 seconds to measure end-tidal carbon dioxide (EtCO2) and respiration rate (RR)
  • Small, portable capnometer — lightweight design fits in the palm of your hand for mobility and convenience during short-term EtCO2 monitoring of adult, pediatric, and infant patients
  • Designed to fit easily onto a breathing circuit
  • Flexible use at multiple environments including pre-hospital, emergency medicine, operating room, and intensive care
  • Rugged design for reliable operation in challenging environments
  • Easy to maintain — no routine calibration required
  • CO2 Range: 0 - 99 mmHg.
  • Respiration Rate Range: 3 - 150 bpm.
  • CO2 Accuracy: 0 - 40 mmHg +/- 2 mmHg; 41 - 99 mmHg 6% of reading.
  • Respiration Rate Accuracy: +/- 1 bpm.
  • Battery Life: 6 hours (Alkaline) or 10 hours (Lithium).
  • Operating Temperature: 23 to 122 °F (-5 to 50 °C).
  • Operating Atmospheric Pressure: 70 - 120 kPa.
  • Operating Humidity: 10 - 95%, non-condensing.
  • Storage Temperature: -22 to 158 °F (-30 to 70 °C).
  • Storage Atmospheric Pressure: 50 to 120 kPa.