Hi,


I recall there being a way to get the unit into Generator-only mode but I can't remember how.

RE: Siemens - Ysio
Added  Oct 8 2022
0 Replies

Hi Any idea on how to get a userguide or manual for siemen ysio DR xray machine pls. Thank you Email Dolbless_4@hotmail.co.uk

RE: Siemens - Ysio
Updated  Jun 5 2020
1 Reply

I'm looking for a service manual for a Siemens Ysio system in digital form. I'm specifically looking for a theory of operation for the alignment of the tube to the table FD. I have a symptom that the machine won't come to ready when pointed at the table bucky but will show ready status if the tube is rotated horizontally roughly 20 degrees. Has anyone else experienced something like this? Thank you in advance for your help.

RE: Siemens - Ysio
Added  Apr 29 2020
0 Replies

Do YSio DR support RAID configuration in its capture console. Can I get some details on this.

RE: Siemens - Ysio
Updated  Nov 14 2019
1 Reply

I need a service manual for the Siemens Ysio (especially for the 3D Top overhead crane). I only have On-site Siemens docs, and that is the installation and operation manual. I have a dropbox account. Thank you, Tim

RE: Siemens - Ysio
0 Replies

I have a Ysio rad room with error code "20551 Flash 80". The room has been rebooted to no avail. Can this problem be resolved by the operator rather than calling in OEM service?

RE: Siemens - Ysio
Updated  Aug 12 2017
3 Replies

What is the optimum EXI value in Siemens DR Ysio? If the values is in range, what is the range? Could you provide jurnals or valid literatures to support the exposure index values stated?

RE: Siemens - Ysio
Updated  Nov 22 2016
3 Replies

was told wall stand detector had to sit idle for 10 hours before a calibration could be performed, true or false?

RE: Siemens - Ysio
Updated  Aug 24 2016
1 Reply

On the Siemens Ysio/Ysio Max, does the wi-D detector charge in both the table and wall bucky? I have seen some documents that say both and other documents just say table and doesn't mention the wall bucky.

Thanks!

RE: Siemens - Ysio
Updated  Apr 14 2016
1 Reply

error message : measured dose is below to limit refer to UM.

actions has been done , checked RAD and configs, cheked collimater, tube is checked , i did free exposure also , always the exposure comes long or wide its not cutted !

any suggestions , i suspect there is board in generator or part of it defective

any one has an idea

, thanks in Advance