AGFA - CP1000
by AGFA

AGFA CP1000 Forums

Updated  Sep 14 2021
1 Reply

I would like to get this schematics on this

RE: AGFA - CP1000
Updated  Sep 17 2020
1 Reply

manual de la procesadora cp 1000

RE: AGFA - CP1000
Updated  Mar 2 2018
2 Replies

Anyone have knowledge of companies that sell the Agfa CP1000 processor parts?? I am in need of the replenishment switch. Thanks, Steve Kopcial

RE: AGFA - CP1000
Added  Nov 7 2017
0 Replies

Is a cuircuit diagram available

RE: AGFA - CP1000
Updated  Jan 11 2017
3 Replies

Hello everyone, I have a cp1000 agfa whose revelator bath is too hot and the film is burned.

I want the service manual thank you

RE: AGFA - CP1000
0 Replies

hi my all films get line when it passes through dryer. i already cleand every thing other than dryer as i can not open the dryer.can some one will tell me how to open the dryer i.e infrared dryer.

 

RE: AGFA - CP1000
Updated  Oct 13 2015
1 Reply

All of the processor fluids (water, fixer, developer) are running out way too fast. No leaks are seen... any troubleshooting ideas? Fluids are running low as fast as we fill them

RE: AGFA - CP1000
0 Replies

I am looking to replace the developer and water tanks in our processor.  Both have developed cracks which are leading to corrosion underneath the tanks.  I would also be interested in replacing the bottles, which are very stained.

Re: the bottles:  I was told that we were not to clean them with anything, but wonder if we could use bleach as long as it was rinsed out well after the cleaning.

Thank you for any help.

 

RE: AGFA - CP1000
4 Replies

On my CP1000 the replenishment pump motor is running, the belts & gears are fine and don't appear to be slipping, the pumps are turning, the impellers are fine, the vertical pipes are not obstructed, I opened the adjusting screws all the way open.  The tanks are full.  When the replenishment is requested, I can hear the speed increase yet no fluid is pumped up the vertical pipes and out.  I have no replenishment, the system does not consume any chemistry.  All 3 pumps behave the same.  Can anyone tell me how fast the pumps/motor should be turning?  I measured the pump drive gear with a digital tach: 93 RPM normal rate and about 200 RPM in replenishment.  The manual says the speed should double which it does but I must assume I am not reaching the desired speed to move fluid.  The speed is about the same with the tanks removed - so not a bad pump problem.  Does anyone know what voltage should be seen at the motor?  Appreciate any thoughts.

RE: AGFA - CP1000
3 Replies

The films are not completely dry when they come out,.  ... and have some scratches on them....comsistent with debris stuck to the rollers but machine was cleaned thoroughly so not sure where this coming from.

thank you

Cristina