Siemens - Acuson X150
Siemens Acuson X150 Forums
Add Ultrasound Systems to My Bench28 Results
Updated Feb 16 2024
Added May 1 2023
0 Replies
QUERO INSTALADORES PARA ESTE EQUIPO
Equipment: ecografo ACUSON X150
RE: Siemens - Acuson X150Updated Jan 10 2023
3 RepliesTurns off 5 min after start up. What is the easiest way to diagnose? Probably change power supply. ? Which one. Will this work with 20 y old ekectronics.
Equipment: Siemens - Acuson X150
RE: Siemens - Acuson X150Updated Apr 16 2022
2 RepliesI have a siemens acuson x150 displaying a caution message with "???????????" after boot, i can only press ok and after that it boots again. please I need help. RE: Siemens - Acuson X150
Updated Dec 4 2021
1 ReplyI have a siemens acuson x150 displaying a caution message with "???????????" after boot, i can only press ok and after that it boots again. Has anyone experienced this? The service manual would be very appreciated also. RE: Siemens - Acuson X150
Updated Mar 1 2021
1 ReplyHello
Acuson X150
Good morning everyone
I have an error display on monitor (no signal)
Ac leds
Ac power green
OCP orange
DC orange
How to check DC/DC power supply
Any possible solution
Kind regards
Thanks RE: Siemens - Acuson X150
Added Jan 25 2021
0 RepliesWe had a power fluctuation, and later the system has resided to boot the windows.
It says ;
Start windows normally
Safe mode
Safe mode with command
Safe mode with networking
Last known configuration
I have tried all of them and none worked.
Please help me
eduanyanwu@gmail.com
+2347069551905 RE: Siemens - Acuson X150
Updated Oct 3 2020
5 RepliesHello I have a device of acuson x150, the problem started at 1st with that the device after it was being turned on while it was still on the splash screen the device kept loading for a long time, and stuck on the splash screen in which it says " system is checking the configuration" I kept waiting for a long time , and 1st thing I attempted to do was I installed new software, but when the device was turned on it was stuck on the same page of checking configurations, after 10 min an error message appeared "upgradetool failed click ok to shutdown error code = 227". I replaced the AC/DC power supply , the device has a new version of MCP power unlike the old versions of acuson x150. After replacement of the MCP power supply the fault is the same, I removed the I/O module and BE board and reinstalled them, the device's control panel started to be unresponsive, I tested the I/O module on another X150 device in another city it was working fine, I returned it and rechecked the BE removing and reinstalling. Finally the control panel started to be responsive but I am still stuck with the original fault of "stay loading on checking configuration splash screen". So does anyone could help me to to fix that issue, I would be grateful.
Have good day
P.S: while the device is loading on the splash screen while attempting to checking system's configuration, I don't hear the sound of relays opening, I used to hear that sound of them while the device is entering the ultrasound application screen. RE: Siemens - Acuson X150
Updated Apr 16 2020
1 ReplyGood day all,
Please kindly assist me Siemens - Acuson X150 User Manual.
Your kind assistance will be appreciated,
Thanks. RE: Siemens - Acuson X150
Updated Mar 5 2020
5 RepliesI am getting a self diagnostics check signal cable no signal error on a Siemens Acuson X150. I have checked the cables to the unit. The only one disconnected the staff report not using and plugging it in does not clear the error. I have rebooted the unit and still have the same error. Siemens is not providing tech support on this unit. Is there a service manual available? Does anyone know how to clear this error? RE: Siemens - Acuson X150