Laboratory Forums

Updated  Mar 26 2024
1 Reply

RE: TROPHON EPR N100010

I am trying to prepare two generation I machines (2012, 2014) for resale and require the cycle count so that the buyer will be able to predict the next PM.  I assume the cycles should be info that can be viewed using sequenced keying on bootup, but there are no directions in the user manual and nothing I have tried has worked so far.  The boot up initial display shows only S/N and software info.   Both machines pass their self texts and proceed into the purge cycle where they continue unless powered down.  Both seem to complete an initial stage of purging after about 15 minutes and then shift into something pretty much the same after a couple of seconds of what sounds like electronic switching.

What I would like is:

* directions for the cycle recall sequence or whatever process is required to find the cycle count;

* an indication of what the normal purging process is and how it might be controlled or prompted to complete while the device is dry and self testing


Thanks

Bruce Raynor


Equipment: TROPHON EPR

RE: Nanosonics - Trophon EPR
Updated  Mar 26 2024
1 Reply

trying to order fan parts for Getinge 5624 serial # J064108

Equipment: j064108

RE: Getinge - 5624
2 Replies

The device the touchscreen is illuminated and flashing and still flashing when i open device i see a1board flashing when i remove a2 board control panel the a1 board still illuminated not flashing 


Equipment: Hettich - EBA 280

RE: Hettich - EBA 280
2 Replies

Sakura Cryo3 Flex cryostat.

I am looking for manuals (service and/or user), PM checklist, or information describing differences in operation, service, or parts between the Flex version and the original version. 

I have been asked to PM a Cryo 3 Flex. I can see a few differences, but I'm not sure what else there might be, and what I would want to do differently in a PM.

RE: Sakura - Tissue-Tek Cryo3
0 Replies

Sakura VIP 6 AI tissue processor. Errors 321 and 324 are not listed in the service manual for the VIP 6 (I haven't seen a service manual for the "AI" version). It appears that these are new codes for the "AI" version of this processor. The description closely matches the description for errors 311 and 314. Does anyone know what the differences might be? Does anyone have a service manual for the VIP 6 AI?

RE: Sakura - TISSUE-TEK VIP 6
Updated  Mar 17 2024
1 Reply

Getting error 3109 Home limit reached on axis 7? Any advice

Equipment: Qiagen - QIAcube

RE: Qiagen - QIAcube
Updated  Mar 13 2024
1 Reply

Hi,

Does anyone know where I can purchase replacement pistons or a replacement piston kit for the New Brunswick INNOVA 4000 benchtop incubator shaker?  Thanks.

Equipment: New Brunswick INNOVA 4000 Benchtop Shaker

RE: New Brunswick Scientific - Innova 4000
Updated  Mar 13 2024
6 Replies

Hi,

Does anyone know what ERROR E31 MOTOR OVERTEMP means for the Sorvall Legend XT centrifuge.  Bad brushes? Problem with the control board or a temperature probe?  Any troubleshooting recommendations would be appreciated.  Thanks.

Equipment: Sorvall Legend XT centrifuge

RE: Sorvall - Legend XT
Added  Mar 12 2024
0 Replies

Cell counter user manual

Equipment: Sysmex - KX-21

RE: Sysmex - KX-21
Added  Mar 11 2024
0 Replies

My equipment hás its screen blocked and ONLY presents the Window with sample result (blood cell count). Mouse and keyboard cant remove this windows. How can I close this windows with keyboard or if there is another way to solve this problem. 


Equipment: Sinothinker - SK8800

RE: Sinothinker - SK8800