GE HealthCare Voluson P8 Forums

Added  Apr 8 2023
0 Replies

Hello i hope you're doing well i have an error on 3D-4D probes which is motor control unit no probe reference position signal detected and this problem for all 3D-4D probes would you help me to solve this problem and i need volusion P8 service manual best regards

Equipment: GE VOLUSION P8

RE: GE HealthCare - Voluson P8
Added  Mar 4 2023
0 Replies

Hi everybody, Can you please advice whats wrong, or what to do? My ultrasound machine GE p8.The unit says following: Motor control unit: No probe reference position signal detected. Thank you for your advice! Razan

Equipment: GE p8

RE: GE HealthCare - Voluson P8
Added  Aug 27 2021
0 Replies

Is there a way to correct a patient ID if entered incorrectly

RE: GE HealthCare - Voluson P8
Updated  Sep 19 2017
1 Reply

How to mute speakers

RE: GE HealthCare - Voluson P8
1 Reply

Does anyone know the procedure to set up a dicom storage server. I'm having trouble connecting, I can ping the server but it won't verify the connection. The server can ping the US unit as well. All advice is welcomed.

RE: GE HealthCare - Voluson P8
Updated  Mar 15 2017
1 Reply

I need to export data to a cd - and it will not write the data. I also need to record in 4d - real time - the machine will only record still images

RE: GE HealthCare - Voluson P8
Updated  Oct 28 2016
1 Reply

Hi all, This is regarding a Voluson P8 issue. The problem is the machine will work fine with some set of linear and Convex probes. If I used another linear or convex probes, it will not work. Probe switching happens, but scan area is not coming instead we can see the back ground. If I use linear probe in the first port, I can hear relay sound ticking continuously. All of the probes which I used are 100% working. I checked in other machines too. I restored the software, reloaded the software in new hard disk, but no use. Please help. Thank you

RE: GE HealthCare - Voluson P8
Updated  Sep 9 2016
2 Replies

Hai,

My Ge voluson p8 machine probes are not detecting,system booting well,can help anybody.

sarath

sarath@ultrasoundindia.com

RE: GE HealthCare - Voluson P8
Added  Aug 28 2016
0 Replies

Does the voluscan P8 have a good cardiology software. Is it a good machine for shared services

RE: GE HealthCare - Voluson P8
Updated  Feb 9 2016
3 Replies

My machine was in a public storage for 2 months. After carefully transporting to my new office it is really sliw! Takes 3 seconds to unfreeze & make & finish a measurement. When I use the depth or any other knob function the image freezes for 3 seconds. I will try deleting all memory but any other suggestions?

RE: GE HealthCare - Voluson P8

Start a Thread

Equipment Name: GE HealthCare - Voluson P8