Episode 5 - Difference Between Options A01, A02, A03 and A04 with M3001A Module

Today we are going to discuss the difference between each option with A01, A02 Nellcor Oximax, A03 Masimo and A04 Nellcor Oximax on the M3001A MMS Module.  We will also show you how to identify the parameters that comes with each option…Standard, C06, C12 and C18.  We will show you where to locate the part identification numbers as well.

In Section M3001A Module Option A01 we will talk about the options and parameters that come with each unit.  First we have A01 Standard, A01C06, A01C12 and A01C18

Here we have Option A01 Standard.  This unit comes with Parameters: 3 or 5 Lead ECG, (Philips) SpO2 and NiBP (Non-Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit. 

Here we have Option A01C06.  This unit comes with Parameters: 3 or 5 Lead ECG, (Philips) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit.

Here we have Option A01C12.  This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Philips) SpO2 and NiBP (Non-Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the corner backside of the unit. 

Here we have Option A01C18. This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Philips) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the corner backside of the unit.


In Section M3001A Module Option A02 (Nellcor Oximax Compatible) we will talk about the options and parameters that come with each unit.  First we have A02 Standard, A02C06, A02C12 and A02C18

Here we have Option A02 Standard.  This unit comes with Parameters: 3 or 5 Lead ECG, (Nellcor Oximax) SpO2 and NiBP (Non-Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit. 

Here we have Option A02C06.  This unit comes with Parameters: 3 or 5 Lead ECG, (Nellcor Oximax) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit.

Here we have Option A02C12.  This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Nellcor Oximax) SpO2 and NiBP (Non-Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit.

Here we have Option A02C18.  This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Nellcor Oximax) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit.

In Section M3001A Module Option A03 (Masimo Compatible) we will talk about the options and parameters that come with each unit.  First we have A03 Standard, A03C06, A03C12 and A03C18
Here we have Option A03 Standard.  This unit comes with Parameters: 3 or 5 Lead ECG, (Masimo) SpO2 and NiBP (Non-Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit. 

Here we have Option A03C06.  This unit comes with Parameters: 3 or 5 Lead ECG, (Masimo) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit.

Here we have Option A03C12.  This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Masimo) SpO2 and NiBP (Non-Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the corner backside of the unit.

Here we have Option A03C18.  This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Masimo) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the corner backside of the unit.

In Section M3001A Module Option A04 (Nellcor Oximax Compatible) we will talk about the options and parameters that come with each unit.  First we have A04 Standard, A04C06, A04C12 and A04C18

Here we have Option A04 Standard.  This unit comes with Parameters: 3 or 5 Lead ECG, (Nellcor Oximax) SpO2 and NiBP (Non-Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit. 

Here we have Option A04C06. This unit comes with Parameters: 3 or 5 Lead ECG, (Nellcor Oximax) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification are and Serial Numbers located on the bottom of the unit.

Here we have Option A04C12.  This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Nellcor Oximax) SpO2 and NiBP (Non-Invasive Blood Pressure). The Product Identification and Serial Numbers are located on the bottom of the unit.

Here we have Option A04C18.  This unit comes with Parameters: 3, 5 or 12 Lead ECG, (Nellcor Oximax) SpO2, NiBP (Non-Invasive Blood Pressure), Temperature and iBP (Invasive Blood Pressure).
The Product Identification and Serial Numbers are located on the bottom of the unit. If you would like to submit your own technical contributions for consideration, please visit pacificmedicalsupply.com/pacfaq-video-request/  